The objectives of this study were to investigate the variability among Listeria monocytogenes strains in response to high-pressure processing, identify the most resistant strain as a potential target of pressure processing, and compare the inactivation kinetics of pressure-resistant and pressure-sensitive strains under a wide range (350 to 800 MPa) of pressure treatments. The pressure resistance of Listeria innocua and nine strains of L. monocytogenes was compared at 400 or 500 MPa and 30 degrees C. Significant variability among strains was observed. The decrease in log CFU/ml during the pressure treatment was from 1.4 to 4.3 at 400 MPa and from 3.9 to >8 at 500 MPa. L. monocytogenes OSY-8578 exhibited the greatest pressure resistance, Scott A showed the greatest pressure sensitivity, and L. innocua had intermediate resistance. On the basis of these findings, L. monocytogenes OSY-8578 is a potential target strain for high-pressure processing efficacy studies. The death kinetics of L. monocytogenes Scott A and OSY-8578 were investigated at 350 and 800 MPa. Survivors at 350 MPa were enumerated by direct plating, and survivors at 800 MPa were enumerated by the most-probable-number technique. Both pressure-resistant and pressure-sensitive strains exhibited non-first-order death behavior, and excessive pressure treatment did not eliminate the tailing phenomenon.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.4315/0362-028x-66.11.2057 | DOI Listing |
Sci Rep
January 2025
Structural Engineering Department, Faculty of Engineering, Ain Shams University, Cairo, Egypt.
Nowadays, Egypt is treating the Nile River Water to produce drinking water, and this process generates large amounts of waste, around 635 million m annually, which is called water treatment plant sludge (WTPS). This WTPS cost the government around 30 million US dollars to return it back to the Nile River in addition to negatively affecting the environment. Therefore, there is an urgent need to find environmentally friendly alternatives that reduce the impact of such an issue.
View Article and Find Full Text PDFDent Mater
January 2025
Department of Prosthodontics and Periodontology, Bauru School of Dentistry, University of São Paulo, Bauru, SP 17012-901, Brazil.
Objectives: To characterize two experimental zirconia bilayer materials compared to their monolithic controls, before and after hydrothermal aging.
Methods: Commercial zirconia powders were utilized to fabricate two bilayer materials: 3Y-TZP+ 5Y-PSZ (3Y+5Y/BI) and 4Y-PSZ+ 5Y-PSZ (4Y+5Y/BI), alongside control groups 3Y-TZP (3Y/C), 4Y-PSZ (4Y/C), and 5Y-PSZ (5Y/C). Compacted specimens were sintered (1550 °C- 2 h, 3 °C/min), and half of them underwent hydrothermal aging (134 °C-20h, 2.
Sensors (Basel)
January 2025
Faculty of Mechanical Engineering, Silesian University of Technology, Konarskiego 18A, 44-100 Gliwice, Poland.
This article presents the authors' design of an electronic stethoscope intended for use during online medical consultations for patient auscultation. The goal of the project was to design an instrument that is durable, user-friendly, and affordable. Existing electronic components were used to create the device and a traditional single-sided chest piece.
View Article and Find Full Text PDFSmall
January 2025
State Key Laboratory of Solid Lubrication, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences, Lanzhou, 730000, China.
Polymer composite materials encounter considerable challenges in sustaining superior tribological properties at high rotational speeds. Inspired by the microstructure of dragonfly wings, a novel thermally stable and ambient pressure curing poly(urea-imide) resin (PURI) with excellent tribological properties has been eco-friendly synthesis using bio-based greener solvents. Furthermore, The PURI composites enhanced with polyether ether ketone (PEEK) and Polytetrafluoroethylene (PTFE) blended fabrics demonstrate excellent mechanical, with tensile strengths exceeding 175 MPa.
View Article and Find Full Text PDFBMC Oral Health
January 2025
Department of Stomatology, The First Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080, China.
Background: Proper torque control is crucial to the outcome of orthodontic treatment. This study aimed to employ finite element analysis to compare the torque capabilities of a novel spherical self-ligating bracket with a lock-hook system against those of commonly used passive self-ligating and conventional bracket systems, as well as to reveal the biomechanical changes in the periodontal ligament (PDL) during torque expression.
Methods: A maxillary right central incisor, along with its PDL and alveolar bone, were modeled.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!