Size and geometry of hepatic radiofrequency lesions.

Eur J Surg Oncol

Department of Surgery, University Hospital of Mont-Godinne, Catholic University of Louvain, Yvoir, Belgium.

Published: December 2003

Aim: To report and compare the size and geometry of hepatic radiofrequency (RF) lesions using the currently available commercial devices.

Methods: A literature search was carried out for the period from January 1st 1990 to June 15th 2003. The commercial suppliers were asked to provide all available data. For each electrode and protocol, size and geometry of single-cycle thermal lesions were registered.

Results: No information at all on size and geometry of the inducible lesions was available for 17 of the 28 current commercial electrodes. Many descriptions of RF lesions are limited to the mean transverse diameter. With normal blood flow, diameter of lesions is often smaller than suggested by the length of the electrode tip or the diameter of the deployed prongs. Lesions are rarely perfect spheres but either ellipses or flattened spheres. Distortion of the RF lesion by nearby blood vessels is very common. Fusion of thermal zones between prongs of expandable electrodes can be incomplete. Blood flow interruption using a Pringle maneuver yields larger lesions that are less distorted and more complete.

Conclusions: There is insufficient experimental data for many electrodes that are currently used in patients. RF companies should provide these data before releasing electrodes for use. For those electrodes for which data exist, coagulation lesions are often smaller, less spherical, less complete and less regular than generally presumed. Accurate knowledge of size and geometry of RF lesions is crucial to prevent local recurrence.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejso.2003.09.012DOI Listing

Publication Analysis

Top Keywords

size geometry
20
lesions
10
geometry hepatic
8
hepatic radiofrequency
8
radiofrequency lesions
8
provide data
8
blood flow
8
lesions smaller
8
size
5
electrodes
5

Similar Publications

Systematic evaluation of adhesives for implant fixation in multimodal functional brain MRI.

MAGMA

January 2025

Translational Research Imaging Center (TRIC), Clinic of Radiology, University of Münster, Albert-Schweitzer-Campus 1, building A16, 48149, Münster, Germany.

Objective: Invasive multimodal fMRI in rodents is often compromised by susceptibility artifacts from adhesives used to secure cranial implants. We hypothesized that adhesive type, shape, and field strength significantly affect susceptibility artifacts, and systematically evaluated various adhesives.

Materials And Methods: Thirty-one adhesives were applied in constrained/unconstrained geometries and imaged with T2*-weighted EPI at 7.

View Article and Find Full Text PDF

Metal nanoparticles are established tools for biomedical applications due to their unique optical properties, primarily attributed to localized surface plasmon resonances. They show distinct optical characteristics, such as high extinction cross-sections and resonances at specific wavelengths, which are tunable across the wavelength spectrum by modifying the nanoparticle geometry. These attributes make metal nanoparticles highly valuable for sensing and imaging in biology and medicine.

View Article and Find Full Text PDF

To accurately model and validate the 6 MV Elekta Compactlinear accelerator using the Geant4 Application for Tomographic Emission (GATE). In particular, this study focuses on the precise calibration and validation of critical parameters, including jaw collimator positioning, electron source nominal energy, flattening filter geometry, and electron source spot size, which are often not provided in technical documentation. Methods: Simulation of the Elekta Compact6 MV linear accelerator was performed using the Geant4 Application for Tomographic Emission (GATE) v.

View Article and Find Full Text PDF

The recycling of low-concentration coal-bed methane (CBM) is environmentally beneficial and plays a crucial role in optimizing the energy mix. In this work, we present a strategy involving pore chemical modification to synthesize a series of bimetallic diamond coordination networks, namely CuIn(ina), CuIn(3-ain), and CuIn(3-Fina) (where ina = isonicotinic acid, 3-ain = 3-amino-isonicotinic acid, and 3-Fina = 3-fluoroisonicotinic acid). Among these, the amino-functionalized CuIn(3-ain) exhibits excellent CH adsorption capacity (1.

View Article and Find Full Text PDF

Perovskite Nanocrystal Self-Assemblies in 3D Hollow Templates.

ACS Nano

January 2025

IBM Research Europe─Zurich, Säumerstrasse 4, 8803 Rüschlikon, Switzerland.

Highly ordered nanocrystal (NC) assemblies, namely, superlattices (SLs), have been investigated as materials for optical and optoelectronic devices due to their unique properties based on interactions among neighboring NCs. In particular, lead halide perovskite NC SLs have attracted significant attention owing to their extraordinary optical characteristics of individual NCs and collective emission processes like superfluorescence (SF). So far, the primary method for preparing perovskite NC SLs has been the drying-mediated self-assembly method, in which the colloidal NCs spontaneously assemble into SLs during solvent evaporation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!