A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Use of the impulse oscillometry system for testing pulmonary function during methacholine bronchoprovocation in horses. | LitMetric

Use of the impulse oscillometry system for testing pulmonary function during methacholine bronchoprovocation in horses.

Am J Vet Res

Laboratory for Functional Investigation, Department of Physiology, Faculty of Veterinary Medicine, University of Liège, Bat B42, Sart Tilman, B-4000 Liège, Belgium.

Published: November 2003

Objective: To compare sensitivity of the impulse oscillometry system (IOS) with that of the conventional reference technique (CRT; ie, esophageal balloon method) for pulmonary function testing in horses.

Animals: 10 horses (4 healthy; 6 with recurrent airway obstruction [heaves] in remission).

Procedure: Healthy horses (group-A horses) and heaves-affected horses (group-B horses) were housed in a controlled environment. At each step of a methacholine bronchoprovocation test, threshold concentration (TC(2SD); results in a 2-fold increase in SD of a value) and sensitivity index (SI) were determined for respiratory tract system resistance (R(rs)) and respiratory tract system reactance (X(rs)) at 5 to 20 Hz by use of IOS and for total pulmonary resistance (RL) and dynamic lung compliance (C(dyn)), by use of CRT.

Results: Bronchoconstriction resulted in an increase in R(rs) at 5 Hz (R(5Hz)) and a decrease in X(rs) at all frequencies. Most sensitive parameters were X(rs) at 5 Hz (X(5Hz)), R(5Hz), and R(5Hz):R(10Hz) ratio; RL and the provocation concentration of methacholine resulting in a 35% decrease in dynamic compliance (PC(35)C(dyn)) were significantly less sensitive than these IOS parameters. The TC(2SD) for X(rs) at 5 and 10 Hz was significantly lower in group-B horses, compared with group-A horses. The lowest TC(2SD) was obtained for X(5Hz) in group-B horses and R(5Hz) in group-A horses.

Conclusions And Clinical Relevance: In contrast to CRT parameters, IOS parameters were significantly more sensitive for testing pulmonary function. The IOS provides a practical and noninvasive pulmonary function test that may be useful in assessing subclinical changes in horses.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.2003.64.1414DOI Listing

Publication Analysis

Top Keywords

pulmonary function
16
group-b horses
12
horses
10
impulse oscillometry
8
oscillometry system
8
testing pulmonary
8
methacholine bronchoprovocation
8
group-a horses
8
respiratory tract
8
tract system
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!