Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To compare sensitivity of the impulse oscillometry system (IOS) with that of the conventional reference technique (CRT; ie, esophageal balloon method) for pulmonary function testing in horses.
Animals: 10 horses (4 healthy; 6 with recurrent airway obstruction [heaves] in remission).
Procedure: Healthy horses (group-A horses) and heaves-affected horses (group-B horses) were housed in a controlled environment. At each step of a methacholine bronchoprovocation test, threshold concentration (TC(2SD); results in a 2-fold increase in SD of a value) and sensitivity index (SI) were determined for respiratory tract system resistance (R(rs)) and respiratory tract system reactance (X(rs)) at 5 to 20 Hz by use of IOS and for total pulmonary resistance (RL) and dynamic lung compliance (C(dyn)), by use of CRT.
Results: Bronchoconstriction resulted in an increase in R(rs) at 5 Hz (R(5Hz)) and a decrease in X(rs) at all frequencies. Most sensitive parameters were X(rs) at 5 Hz (X(5Hz)), R(5Hz), and R(5Hz):R(10Hz) ratio; RL and the provocation concentration of methacholine resulting in a 35% decrease in dynamic compliance (PC(35)C(dyn)) were significantly less sensitive than these IOS parameters. The TC(2SD) for X(rs) at 5 and 10 Hz was significantly lower in group-B horses, compared with group-A horses. The lowest TC(2SD) was obtained for X(5Hz) in group-B horses and R(5Hz) in group-A horses.
Conclusions And Clinical Relevance: In contrast to CRT parameters, IOS parameters were significantly more sensitive for testing pulmonary function. The IOS provides a practical and noninvasive pulmonary function test that may be useful in assessing subclinical changes in horses.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.2460/ajvr.2003.64.1414 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!