Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A photometric immunosensor that can be used for on-site diagnosis has been constructed. The sensor system was assembled by partially superimposing a nitrocellulose membrane strip (the lower) containing an immobilized antigen on the surface with a glass fiber membrane strip (the upper) including two electrodes on the opposite surfaces. To amplify the signal, we introduced a liposome, containing ruthenium molecules trapped in the core, chemically coupled to an antibody specific to the analyte (e.g. Legionella antigen). In the presence of the analyte, immune complexes were formed by antigen-antibody reactions upon addition of the immuno-liposome into a sample. This mixture was then absorbed by the capillary action from the bottom of the membrane strip. The liposome particles in the complexes were carried by a medium through the antigen pad without interaction, while free immuno-liposome was trapped by immune reactions on the pad surfaces. The aqueous medium influx into the glass pad dissolved a detergent pre-located within the compartment and the liposome rupture thereby released ruthenium molecules into the solution. The molecules were oxidized on the electrode surfaces and produced an electro-chemiluminescence (ECL) in proportion to the analyte concentration. The signal generation based on ECL resulted in an exponential dose-response pattern and the analyte detection limit of 2 ng/ml was approximately 10-fold more sensitive than that obtained from a conventional system.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0956-5663(03)00207-0 | DOI Listing |