A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Monolithic valves for microfluidic chips based on thermoresponsive polymer gels. | LitMetric

The direct preparation of thermoresponsive monolithic copolymers by photopatterning of a liquid phase consisting of an aqueous solution of N-isopropylacrylamide, N-ethylacrylamide, N,N'-methylenebisacrylamide, and 4,4'-azobis(4-cyanovaleric acid) has been studied and the products used as valves within the channels of microfluidic devices. The volume change associated with the polymer phase transition at its lower critical solution temperature (LCST) leads to the rapid swelling and the deswelling of the 2.5% cross-linked monolithic gel thus enabling the polymer to close or open the channel and to function as a nonmechanically actuated valve. The LCST at which the valve switches was easily adjusted within a range of 35 degrees C-74 degrees C by varying the proportions of the monovinyl monomers in the polymerization mixture. The closed valve holds pressures of up to 18 MPa without noticeable dislocation, structural damage, or leakage. In contrast, following deswelling by raising the temperature above LCST the valve offers no appreciable flow resistance since its large, micrometer-size pores are open. Laser-triggered photobleaching of a fluorescent dye contained in the liquid phase enabled monitoring of flow through the device and determination of the times required to open and close the valve. The valves are characterized by very fast actuation times in a range of 1-4 s depending on the type of device. No changes in performance were observed even after repeated open-close cycling of the valves.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.200305577DOI Listing

Publication Analysis

Top Keywords

liquid phase
8
temperature lcst
8
lcst valve
8
valve
5
monolithic valves
4
valves microfluidic
4
microfluidic chips
4
chips based
4
based thermoresponsive
4
thermoresponsive polymer
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!