A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Laser-induced breakdown spectroscopy for on-line engine equivalence ratio measurements. | LitMetric

Laser-induced breakdown spectroscopy for on-line engine equivalence ratio measurements.

Appl Spectrosc

Department of Mechanical Engineering, University of Maryland, College Park, Maryland, USA.

Published: September 2003

Laser-induced breakdown spectroscopy (LIBS) has been used to measure the equivalence ratio of a spark-ignited engine in a laboratory setting. Spectral features of C (711.3 nm), O (776.6 nm), N (746.3 and 743.8 nm), and CN (broad emission 707-734 nm) were used to quantify the equivalence ratio over a range from phi = 0.8 to phi = 1.2. The C/N and C/O peak ratios were found to be successful measurement metrics, compared with a standard exhaust gas oxygen analyzer, for averaged measurements. Some variation in the measurements was observed as a function of engine load. Single-shot data based on a CN/air peak ratio were evaluated using a separate calibration from averaged measurements, and the average of the single-shot data was found to agree well with the exhaust gas oxygen analyzer. The scatter in the single-shot data was substantially higher at lower equivalence ratios. The measurements including the CN peak were slightly sensitive to load, possibly due to pressure changes in the sample as the load increases, or possibly due to changes in the particle size distribution in the gas stream.

Download full-text PDF

Source
http://dx.doi.org/10.1366/00037020360696071DOI Listing

Publication Analysis

Top Keywords

equivalence ratio
12
single-shot data
12
laser-induced breakdown
8
breakdown spectroscopy
8
exhaust gas
8
gas oxygen
8
oxygen analyzer
8
averaged measurements
8
measurements
5
spectroscopy on-line
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!