A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Magnetically integrated microporous implant: safety and efficacy of secondary posting. | LitMetric

Objective: To evaluate the surgical technique and morbidity related to secondary posting of a previously implanted 12-mm microporous high-density polyethylene implant (MEDPOR) and the enhanced motility associated with magnetic coupling of the prosthesis and the implant in a rabbit model.

Methods: Eight New Zealand rabbits underwent primary evisceration surgery with implantation of a 12-mm microporous high-density polyethylene implant. At 6 weeks, a 4 x 6-mm stainless steel, titanium-coated post was secondarily inserted in 6 rabbit eyes using a bilevel incision. Four weeks after the second surgery, 3 rabbits were fitted with a magnet-embedded prosthesis. Motility was measured by evaluating lateral prosthetic excursion during direct observation. At 3, 6, and 12 months the implants and surrounding tissues were harvested for histopathologic examination.

Results: Secondary placement of the post within the implant was accomplished without difficulty. No signs of erosion, dehiscence, or extrusion were found after a12-month follow-up in any of the study eyes. Clinical grading documented increased movement of the magnetically coupled prostheses compared with nonmagnetically integrated control eyes.

Conclusion: This study establishes the safety of secondary posting and the efficacy of magnetically integrated microporous high-density polyethylene implants in the rabbit model.

Clinical Relevance: This technique may offer an alternative to patients with previously implanted microporous high-density polyethylene implants seeking enhanced cosmesis and prosthetic motility.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archopht.121.11.1596DOI Listing

Publication Analysis

Top Keywords

microporous high-density
16
high-density polyethylene
16
secondary posting
12
magnetically integrated
8
integrated microporous
8
12-mm microporous
8
polyethylene implant
8
polyethylene implants
8
microporous
5
implant
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!