Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Bioartificial liver assist devices (BALs) offer an opportunity for critical care physicians and transplant surgeons to stabilize patients prior to orthotopic liver transplantation. Such devices may also act as a bridge to transplant, providing liver support to patients awaiting transplant, or as support for patients post living-related donor transplant. Four BAL devices that rely on hepatocytes cultured in hollow fiber membrane cartridges (Circe Biomedical HepatAssist(r), Vitagen ELADTM, Gerlach BELS, and Excorp Medical BLSS) are currently in various stages of clinical evaluation. Comparison of the four devices shows that several unique approaches based upon the same overall system architecture are possible. Preliminary results of the Excorp Medical BLSS Phase I safety evaluation at the University of Pittsburgh, after treating four patients (F, 41, acetominophen-induced, two support periods; M, 50, Wilson's disease, one support period; F, 53, acute alcoholic hepatitis, two support periods; F, 24, chemotherapy-induced, one support period, are presented. All patients presented with hypoglycemia and transient hypotension at the start of extracorporeal perfusion. Hypoglycemia was treated by IV dextrose and the transient hypotension responded positively to IV fluid bolus. Heparin anticoagulation was used only in the second patient. No serious or adverse events were noted in the four patients. Moderate Biochemical response to support was noted in all patients. More complete characterization of the safety of the BLSS requires completion of the Phase I safety evaluation.
Download full-text PDF |
Source |
---|
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!