A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Discharge patterns of preganglionic neurones with axons in a cardiac vagal branch in the rat. | LitMetric

Discharge patterns of preganglionic neurones with axons in a cardiac vagal branch in the rat.

Exp Physiol

Department of Human Anatomy and Physiology, University College Dublin, Earlsfort Terrace, Dublin 2, Ireland.

Published: November 2003

The fibre types that run in a vagal branch projecting to the rat heart are described in this study. In order to obtain spontaneous discharge in this vagal branch and optimal recording conditions, we compared the decerebrate state to urethane, urethane-chloralose and pentobarbital-chloralose anaesthesia with regard to level of chronotropic cardiac vagal tone. Administration of atropine (2 mg kg(-1), I.V.) significantly decreased baseline cardiac interval only in the decerebrate and urethane-anaesthetised rat (by 0.018 +/- 0.001 s and 0.019 +/- 0.002 s, respectively). As a result of these experiments, urethane was chosen as the anaesthetic for all subsequent studies. Using a heart rate signal-averaging method we demonstrated that rat cardiac vagal preganglionic neurones innervating the sinoatrial node should have an expiratory discharge pattern, as reported in other species. However, only 5 % of chronotropic vagal tone was found to be subject to respiratory sinus arrhythmia. A suction microelectrode method, combined with spike-triggered averaging, was employed to record activity from a total of 58 vagal afferents that had axons in this branch. Approximately 75 % of these latter sensory fibres displayed cardiac rhythm. In a separate study we also recorded 318 preganglionic neurones with axons in the right cardiac vagal branch of the rat. Respiratory-modulated preganglionic units were statistically less common than tonically firing units. Six preganglionic subtypes were categorised according to conduction velocity and respiratory discharge pattern. Myelinated B-fibre and unmyelinated C-fibre types were found to be equally prevalent and equally likely to be reflexly excited during the pulmonary chemoreflex and the peripheral arterial chemoreflexes. The electrophysiological analysis has shown how diverse the discharge patterns of the preganglionic neurones or interneurones are whose axons course in the right cardiac vagal branch of the rat. The results of these experiments demonstrate the usefulness of combining spike discrimination with multiple spike-triggered averaging to simultaneously record B and C centrifugal vagal efferents.

Download full-text PDF

Source
http://dx.doi.org/10.1113/eph8802590DOI Listing

Publication Analysis

Top Keywords

cardiac vagal
20
vagal branch
20
preganglionic neurones
16
branch rat
12
vagal
10
discharge patterns
8
patterns preganglionic
8
neurones axons
8
axons cardiac
8
vagal tone
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!