This study compared magnetic resonance imaging (MRI) and surface electromyography (EMG) to evaluate the effect of knee angle upon plantar flexion activity in the triceps surae muscles [medial & lateral gastrocnemius (MG, LG) and the soleus (SOL)]. Two weight & height matched groups performed identical protocols, twelve (6M, 6F) in the MRI group, twelve (8M, 4F) in the EMG group. Subjects plantar flexed dynamically for 2 min at 25% of 1-repetition maximum voluntary contraction (1-RM). Exercise was performed with the knee extended (0 degrees flexion), flexed (90 degrees ), and partially flexed (45 degrees ). In the MRI group spin-echo images were acquired before and immediately following each exercise session. T(2) times, calculated at rest and after exercise by fitting the echoes to a monoexponential decay pattern with a least-squares algorithm, were compared with EMG data. In the EMG group a bipolar electrode was used to collect samples were from the MG, LG, SOL, and anterior tibialis (TA) during exercise at each knee angle, MRI also examined the peroneus (PER). At 0 degrees flexion MRI demonstrated a significant post-exercise T(2) increase in the MG (p < or = 0.001), LG (p < or = 0.001), and PER (p < or = 0.01), with no T(2) change in the SOL or TA. At 90 degrees flexion there was a significant T(2) increase in the SOL (p < or = 0.001) with no significant T(2) change in the MG, LG, PER, or TA. At 45 degrees T(2) increased significantly in the SOL (p < or = 0.001) and LG (p < or = 0.05), but not the MG, PER, or TA. EMG produced similar results with the exception that there was significant activity in the TA during the relaxation cycle of the 90 degrees protocol. We conclude that: 1) Soleus activity is measurable by MRI; and 2) MRI and EMG produce similar results from different physiological sources, and are therefore complementary tools for evaluating muscle activity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0730-725x(03)00183-8 | DOI Listing |
Knee Surg Sports Traumatol Arthrosc
January 2025
Orthopaedic Robotics Laboratory, Departments of Bioengineering and Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
Purpose: To quantify the effect of increasing the posterior tibial slope (PTS) on knee kinematics and the resultant medial and lateral meniscal forces.
Methods: In this controlled laboratory study, a 6 degrees of freedom (DOF) robotic testing system was used to apply external loading conditions to seven fresh-frozen human cadaveric knees: (1) 200-N axial compressive load, (2) 5-N m internal tibial +10-N m valgus torque and (3) 5-N m external tibial + 10-N m varus torque. Knee kinematics and the resultant medial and lateral meniscal forces were acquired for two PTS states: (1) native PTS and (2) increased PTS.
Am J Sports Med
January 2025
Twin Cities Orthopedics, Edina, Minnesota, USA.
Background: Anterior cruciate ligament (ACL) stress techniques-including single-leg stress radiographs, Telos, and KT-1000 arthrometer-are highly accessible and can provide additional diagnostic information to assess ACL and ACL graft integrity. The degree of anterior tibial translation (ATT) may be useful in guiding treatment when a diagnosis on magnetic resonance imaging is not conclusive or for judging if additional treatments, such as anterolateral complex augmentation, may be necessary.
Purpose/hypothesis: The purpose of this study was to evaluate the effect of increasing posterior tibial slope (PTS) on baseline tibial position (BTP) and side-to-side differences (SSD) in ATT.
BMC Musculoskelet Disord
January 2025
Department of Orthopedic Surgery, The 3rd Hospital of Hebei Medical University, Hebei, Shijiazhuang, 050051, P.R. China.
Background: It is known that open wedge high tibial osteotomy (OWHTO) may lead to progression of patellofemoral degeneration due to descent of the patellar height. However, the difference in patellofemoral joint (PFJ) loads with normal daily activity between uniplane and biplane osteotomies is unclear. The purpose of this study was to reveal the differences in PFJ biomechanics between uniplane and biplane OWHTO using finite element analysis (FEA).
View Article and Find Full Text PDFBMC Med Educ
January 2025
Institute of Health and Wellbeing, Federation University, Ballarat, Australia.
Front Bioeng Biotechnol
December 2024
Shi's Center of Orthopedics and Traumatology (Institute of Traumatology, Shuguang Hospital), Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese Medicine, Shanghai, China.
Introduction: Accurate joint moment analysis is essential in biomechanics, and the integration of direct collocation with markerless motion capture offers a promising approach for its estimation. However, markerless motion capture can introduce varying degrees of error in tracking trajectories. This study aims to evaluate the effectiveness of the direct collocation method in estimating kinetics when joint trajectory data are impacted by noise.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!