We measured the physical imaging performance of a 41 x 41 cm2 amorphous silicon flat panel detector designed for angiographic and R&F imaging applications using methods from the emerging IEC standard for the measurement of detective quantum efficiency (DQE) in digital radiographic detectors. Measurements on 12 production detectors demonstrate consistent performance. The mean DQE at the detector center is about 0.77 at zero frequency and 0.27 at the Nyquist frequency (2.5 cycles/mm) when measured with a 7 mm of Al HVL spectrum at about 3.6 microGy. The mean MTF at the center of the detector for this spectrum is 0.24 at the Nyquist frequency. For radiographic operation all 2048 x 2048 detector elements are read out individually. For fluoroscopy, the detector operates in two 30 frame per second modes: either the center 1024 x 1024 detector elements are read out or the entire detector is read out with 2 x 2 pixel binning. A model was developed to predict differences in performance between the modes, and measurements demonstrate agreement with the model. Lag was measured using a quasi-equilibrium exposure method and was found to be 0.044 in the first frame and less than 0.007 after 1 s. We demonstrated that it is possible to use the lag data to correct for temporal correlation in images when measuring DQE with a fluoroscopic imaging technique. Measurements as a function of position on the detector demonstrate a high degree of uniformity. We also characterized dependences on spectrum, exposure level, and direction. Finally, we measured the DQE of a current state of the art image intensifier/CCD system using the same method as for the flat panel. We found the image intensifier system to have lower DQE than the flat panel at high exposure levels and approximately equivalent DQE at fluoroscopic levels.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.1609151DOI Listing

Publication Analysis

Top Keywords

flat panel
16
detector
9
performance cm2
8
cm2 amorphous
8
amorphous silicon
8
silicon flat
8
detector designed
8
designed angiographic
8
angiographic r&f
8
r&f imaging
8

Similar Publications

This study evaluated the growth performance of and microalgae cultivated in diluted liquid digestate supplemented with CO, comparing their efficiency to that of a conventional synthetic media. The presence of an initial concentration of ammonium of 125 mg N-NH .L combined with the continuous injection of 1% v/v CO enhanced the optimal growth responses and bioremediation potential for both strains in 200-mL cultures.

View Article and Find Full Text PDF

Light-driven biotransformations in recombinant cyanobacteria benefit from the atom-efficient regeneration of reaction equivalents like NADPH from water and light by oxygenic photosynthesis. The self-shading of photosynthetic cells throughout the reaction volume, along with the need for extended light paths, limits adequate light supply and significantly restricts the potential for upscaling. Here, we present a flat panel photobioreactor (1 cm optical path length) as a scalable system to provide efficient illumination at high cell densities.

View Article and Find Full Text PDF

Centimeter-Sized CsPbBr Single-Crystal Films for Energy-Resolved Radiation Detection.

ACS Appl Mater Interfaces

January 2025

Beijing Key Laboratory of Construction-Tailorable Advanced Functional Materials and Green Applications Experimental Center of Advanced Materials, School of Materials Science and Engineering, Beijing Institute of Technology, Beijing 100081, China.

Metal halide perovskites (MHPs) are promising materials for radiation detection. Compared with polycrystalline films, single crystals (SCs) have lower defect density, higher carrier mobility, and lifetime. However, the direct synthesis of MHP SCs for large-area flat panel imaging detectors remains challenging.

View Article and Find Full Text PDF

Stoma surgery is frequently used to treat conditions such as colorectal cancer and inflammatory diseases. While it can extend patients' lives, it often introduces challenges that negatively affect quality of life. Convex skin barriers are commonly recommended for managing flat or retracted stomas and addressing irregular peristomal surfaces, such as creases or folds.

View Article and Find Full Text PDF

Background: Dedicated breast computed tomography (bCT) systems offer detailed imaging for breast cancer diagnosis and treatment. As new bCT generations are developed, it is important to evaluate their imaging performance and dose efficiency to understand differences over previous models.

Purpose: To characterize the imaging performance and dose efficiency of a second-generation (GEN2) bCT system and compare them to those of a first-generation (GEN1) system.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!