Multislice helical CT offers several retrospective choices of longitudinal (z) resolution at a given detector collimation setting. We sought to determine the effect of z resolution on the performance of a computer-aided colonic polyp detector, since a human reader and a computer-aided polyp detector may have optimal performances at different z resolutions. We ran a computer-aided polyp detection algorithm on phantom data sets as well as data obtained from a single patient. All data were reconstructed at various slice thicknesses ranging from 1.25 to 10 mm. We studied the performance of the detector at various ranges of polyp sizes using free-response receiver-operating characteristic analyses. We also studied contrast-to-noise ratios (CNR) as a function of slice thickness and polyp size. For the phantom data, reducing the slice thickness from 5 to 1.25 mm improves sensitivity from 84.5% to 98.3% (all polyps), from 61.4% to 95.5% (polyps in the range [0, 5) mm) and from 97.7% to 100% (polyps in the range [5, 10) mm) at a false positive rate of 20 per data set. For polyps larger than 10 mm, there is no significant improvement in detection sensitivity when slice thickness is reduced. CNRs showed expected behavior with slice thickness and polyp size, but in all cases remained high (> 4). The results for the patient data followed similar patterns to that of the phantom case. Thus we conclude that for this detector, the optimal slice thickness is dependent upon the size of the smallest polyps to be detected. For detection of polyps 10 mm and larger, reconstruction of 5 mm sections may be sufficient. Further study is required to generalize these results to a broader population of patients scanned on different scanners.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1118/1.1599985 | DOI Listing |
Cureus
December 2024
Division of Dental Anesthesiology, Faculty of Dentistry Graduate School of Medicine and Dental Sciences, Niigata University, Niigata, JPN.
Background There are many reports of anatomical and physiological studies on trigeminal ganglion neurons, but few studies have analyzed temporal changes in the excitation of the trigeminal ganglion. This study aimed to establish an experimental system for spatial and temporal imaging analysis of the excitatory dynamics of trigeminal ganglion cells evoked by stimulation of a peripheral branch of the trigeminal nerve. Methods After excision of the trigeminal ganglion with the inferior alveolar nerve (IAN) from Sprague Dawley rats (seven to nine weeks old), 400-µm-thick slices of the trigeminal ganglion with the IAN were prepared.
View Article and Find Full Text PDFDiagnostics (Basel)
December 2024
Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, Seoul 08826, Republic of Korea.
: Accurate volumetric assessment of lung nodules is an essential element of low-dose lung cancer screening programs. Current guidance recommends applying specific thresholds to measured nodule volume to make the following clinical decisions. In reality, however, CT scans often have heterogeneous slice thickness which is known to adversely impact the accuracy of nodule volume assessment.
View Article and Find Full Text PDFJ Endourol
January 2025
Faculty of Medicine, Department of Urology, Namik Kemal University, Tekirdag, Turkey.
Excessive kidney mobility is an underestimating challenge for surgeons during retrograde intrarenal surgery (RIRS) and extracorporeal shock wave lithotripsy (ESL). There is no technique approved as a gold standard procedure for reducing excessive kidney mobility. The study aimed to uncover predictive factors for determining excessive renal mobility by utilizing clinicodemographic characteristics and noncontrast computed tomography (NCCT) data.
View Article and Find Full Text PDFEur J Radiol
January 2025
Department of Radiology, Hebei General Hospital, 348 Heping West Road, Shijiazhuang 050051, Hebei, China. Electronic address:
Purpose: This study systematically evaluated the diagnostic performance of dual-energy computed tomography (DECT) quantitative parameters in detecting cervical lymph node metastasis in patients with papillary thyroid cancer (PTC).
Method: We searched PubMed, Embase, Web of Science, Cochrane Library, China National Knowledge Infrastructure, and Wanfang Data databases for relevant original studies from database inception to March 2024. The quality of the included studies was evaluated using the QUADAS-2 tool.
Ann Plast Surg
November 2024
Dr Swanson is a plastic surgeon in private practice in Leawood, KS.
Background: Electromagnetic treatments have recently been combined with radiofrequency to reduce the fat layer and simultaneously increase muscle thickness. Studies report treatment efficacy, using photographs and imaging methods.
Methods: A literature review was conducted.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!