Improved HPLC method for carbohydrate-deficient transferrin in serum.

Clin Chem

Department of Clinical Neuroscience, Karolinska Institutet and Hospital, SE-171 76 Stockholm, Sweden.

Published: November 2003

Background: There is need for a reference method for transferrin glycoforms in serum to which routine immunologic methods for the alcohol marker carbohydrate-deficient transferrin (CDT) can be traceable. We describe an improved HPLC method for transferrin glycoforms.

Methods: Transferrin was iron-saturated by mixing the serum with ferric nitrilotriacetic acid, and lipoproteins were precipitated with dextran sulfate and calcium chloride. Separation of glycoforms was performed on a SOURCE 15Q anion-exchange column using salt gradient elution. Quantification relied on selective absorbance of the iron-transferrin complex at 470 nm. The relative amount of each glycoform was calculated as a percentage of the area under the curve, using baseline integration.

Results: The HPLC system provided reproducible separation and quantification of the asialo-, monosialo-, disialo-, trisialo-, tetrasialo-, pentasialo-, and hexasialotransferrin glycoforms. Most importantly, disialo- and trisialotransferrin were almost baseline separated. The intra- and interassay CV for disialotransferrin were <5%. Serum and the pretreated samples were stable for at least 2 days at 22 or 4 degrees C. Sera from 132 healthy controls contained [mean (SD)] 1.16 (0.25)% disialotransferrin, 4.77 (1.36)% trisialotransferrin, 80.18 (2.01)% tetrasialotransferrin, and 13.88 (1.69)% pentasialo- + hexasialotransferrin. In some cases of a high (>6%) trisialotransferrin, monosialotransferrin was detected at <0.25%. Asialotransferrin was not detected in control sera, but was detected in 57% of chronic heavy drinkers and in 62% of sera with >/=2% disialotransferrin.

Conclusions: The HPLC method fulfills the requirements of a preliminary reference method for CDT and should work for any combination of serum transferrin glycoforms. This method could also be useful for confirming positive CDT results by immunoassays in medico-legal cases.

Download full-text PDF

Source
http://dx.doi.org/10.1373/clinchem.2003.023341DOI Listing

Publication Analysis

Top Keywords

hplc method
12
improved hplc
8
carbohydrate-deficient transferrin
8
reference method
8
method transferrin
8
transferrin glycoforms
8
method
6
transferrin
6
method carbohydrate-deficient
4
serum
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!