Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A novel scheme for performing infrared multiphoton dissociation (IRMPD) is presented in which a hollow fiber waveguide (HFWG) is used to transmit IR radiation into the ion storage region of a mass spectrometer. Efficient dissociation of oligonucleotide and protein ions is demonstrated on an ESI-FTICR instrument in which IRMPD is performed in the external ion reservoir and on a quadrupole ion trap. Using a simple optical scheme consisting of a single focusing lens and an x, y translator, the 10.6-microm IR laser beam, initially 3.5 mm in diameter, is focused into the vacuum-sealed HFWG. The small internal diameter and the high transfer efficiency of the waveguide allow IR radiation of high power density to be employed for IRMPD. In studies performed on a quadrupole ion trap, a 500-microm-i.d. waveguide was used as a medium to transmit IR radiation directly through a 700-microm orifice in the ring electrode. Efficient IRMPD of both a 12-mer oligonucleotide and the protein melittin were performed at laser powers of 0.5 and 3.2 W, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac030157k | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!