Background: Exposure to metal-containing particulate matter has been associated with adverse pulmonary responses. Metals in particulate matter are soluble, hence are readily recovered in urine of exposed individuals. This study investigated the association between urinary metal concentrations and the fractional concentration of expired nitric oxide (F(E)NO) in boilermakers (N = 32) exposed to residual oil fly ash (ROFA).
Methods: Subjects were monitored at a boiler overhaul site located in the New England area, USA. F(E)NO and urine samples were collected pre- and post-workshift for 5 consecutive workdays. Metals investigated included vanadium (V), chromium (Cr), manganese (Mn), nickel (Ni), copper (Cu), and lead (Pb).
Results: The median F(E)NO was 7.5 ppb (95% CI: 7.4-8.0), and the median creatinine-adjusted urinary metal concentrations (mug/g creatinine) were: vanadium, 1.37; chromium, 0.48; manganese, 0.30; nickel, 1.52; copper, 3.70; and lead, 2.32. Linear mixed-effects models indicated significant inverse exposure-response relationships between log F(E)NO and the log-transformed urinary concentrations of vanadium, manganese, nickel, copper, and lead at several lag times, after adjusting for smoking status.
Conclusions: Urine samples may be utilized as a biomarker of occupational metal exposure. The inverse association between F(E)NO and urinary metal concentrations suggests that exposure to metals in particulate matter may have an adverse effect on respiratory health.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/ajim.10305 | DOI Listing |
Sci Rep
January 2025
Praxis Dr.Carmine, Etzelstrasse 21, Pfaeffikon SZ, 8808, Switzerland.
Spot-urinary biomarkers are crucial in medical, epidemiological, and environmental studies, but their variability due to hydration levels requires precise dilution adjustments. Traditional methods, like conventional creatinine correction (CCRC), are limited in compensating for variations in urine concentration, causing substantial inconsistencies, particularly at the extremes of the diuresis spectrum. While restricting the creatinine (CRN) range to 0.
View Article and Find Full Text PDFWorld J Urol
January 2025
Department of Urology, Azienda Socio Sanitaria Territoriale Lariana, Como, Italy.
Purpose: To compare the effect on sexual function of ejaculation-sparing enucleation of the prostate using Thulium: YAG laser (ES-ThuLEP) versus continuous-wave Thulium Fiber Laser (ES-ThuFLEP).
Methods: 112 patients with lower urinary tract symptoms secondary to benign prostatic hyperplasia who wished to preserve ejaculation were treated. 58 patients underwent ES-ThuLEP (Group A) using the Cyber TM generator.
Sci Rep
January 2025
Department of Internal Medicine, Bursa Sehir Training and Research Hospital, University of Health Sciences, Bursa, Turkey.
Primary hyperparathyroidism (pHPT) is marked by mineral imbalances, often leading to nephrolithiasis and osteoporosis. While imaging remains the cornerstone for stone detection, there is growing interest in biochemical markers that could enhance diagnostic accuracy. This study investigates the calcium-to-magnesium (Ca/Mg) ratio as a novel biomarker for nephrolithiasis, comparing its utility to traditional 24-h urinary calcium excretion and exploring its broader clinical implications.
View Article and Find Full Text PDFJ Trace Elem Med Biol
January 2025
College of Life Sciences, Anhui Normal University, Wuhu, Anhui 241000, China.
Background: Cadmium (Cd) is a toxic heavy metal present in environment that has potential to instigate renal toxicity. Didymin (DDM) is a natural flavone, which shows anti-oxidant, anti-inflammatory and antiapoptotic nature. Therefore, the current study was formulated to appraise attenuative potential of DDM against Cd instigated nephrotoxicity.
View Article and Find Full Text PDFACS Appl Bio Mater
January 2025
College of Pharmacy and Inje Institute of Pharmaceutical Sciences and Research, Inje University, Gimhae 50832, Republic of Korea.
Urinary tract infections are among the most common nosocomial infections, with the majority being catheter-associated urinary tract infections (CAUTIs). This study demonstrated that an antimicrobial and antibiofilm urinary catheter containing zinc oxide-carbon nanotubes (ZnO-CNT) can inhibit CAUTIs in patients. ZnO-CNT polymers were synthesized by mixing ZnO and CNT using a high-shear mixer, and the synthesized ZnO-CNT polymers were incorporated into a silicone matrix to produce a ZnO-CNT urinary catheter.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!