Unlabelled: We compared, in volunteers, the oxygenation achieved by tidal volume breathing (TVB) over a 3-min period after maximal exhalation with that achieved by TVB alone. Twenty-three healthy volunteers underwent the two breathing techniques in a randomized order. A circle absorber system with an oxygen flow of 10 L/min was used. The end-expiratory oxygen concentration (EEO(2)) was monitored at 15-s intervals up to 3 min. TVB after maximal exhalation produced EEO(2) values of 68% +/- 5%, 75% +/- 5%, and 79% +/- 4% at 30, 45, and 60 s, respectively, which were significantly larger (P < 0.05) than the corresponding values obtained with TVB alone (58% +/- 5%, 66% +/- 6%, and 71% +/- 5%, respectively). In both techniques, the EEO(2) increased exponentially, with time constants of 35 s during TVB after maximal exhalation versus 58 s during TVB without prior maximal exhalation. In conclusion, maximal exhalation before TVB can hasten preoxygenation by decreasing the nitrogen content of the functional residual capacity, with a consequent increase of EEO(2) to approximately 70% in 30 s and 80% in 60 s.
Implications: Oxygenation by using maximal exhalation before tidal volume breathing produced a significantly faster increase in end-expiratory oxygen concentration than oxygenation with tidal volume breathing alone.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1213/01.ANE.0000082528.93345.B9 | DOI Listing |
J Vis Exp
December 2024
Laboratory of Exercise Physiology, Department of Kinesiology, School of Health Sciences, Faculty of Medicine, Pontificia Universidad Católica de Chile;
J Asthma Allergy
December 2024
Respiratory Medicine, University Hospital of Liège, Liège, Belgium.
Introduction: Physical inactivity due to shortness of breath is common among patients with uncontrolled asthma. We evaluated the body mass composition and exercise capacity of patients with poorly controlled asthma, despite maximal inhalation therapy.
Methods: We recruited 56 patients from the Asthma Clinic of the University Hospital of Liège between September 2020 and December 2023, and 14 healthy subjects.
Cureus
November 2024
Department of Pulmonary Medicine, King's College Hospital, Dubai, ARE.
Middle Eastern countries, such as the United Arab Emirates and Oman, are affected by frequent dust storms and extreme hot climatic conditions, which can exacerbate respiratory conditions. These environmental factors are particularly injurious to asthmatic patients, as they can aggravate small airway disease (SAD), leading to increased morbidity and healthcare challenges. The evaluation of maximal mid-expiratory flow (MEF-25) as a diagnostic and therapeutic tool for early-stage small airway dysfunction is of significant clinical importance, particularly in hot and arid metropolitan environments where dusty conditions exacerbate pulmonary issues.
View Article and Find Full Text PDFJ Thorac Dis
November 2024
Department of Thoracic Surgery, The Affiliated Hospital of Yangzhou University, Yangzhou University, Yangzhou, China.
Background: The identification of volatile organic compounds (VOCs) in exhaled breath has garnered significant research attention as a means of screening and diagnosing lung cancer in recent decades. However, there is no universally accepted protocol for the collection of breath samples to measure VOCs in the clinical context. The purpose of this study was to summarize the current sampling techniques used to obtain VOCs from exhaled breath specifically in the context of lung cancer screening and diagnosis.
View Article and Find Full Text PDFBiosens Bioelectron
March 2025
International School of Engineering (ISE), Biomedical Materials and Devices for Revolutionary Integrative Systems Engineering Research Unit, Chulalongkorn University, Bangkok, 10330, Thailand. Electronic address:
This work presents a ZnO-coated no-core optical fiber sensor (OFS) designed for the highly sensitive detection of acetone vapor. Acetone is a key biomarker for diabetes, which is linked to blood glucose levels and can be detected non-invasively through breath analysis. The OFS utilizes a no-core fiber (NCF) as the sensing region, coated with a thin layer of ZnO nanoparticles to enhance evanescent field interaction with the VOCs at the fiber interface.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!