Controlled hypotension and minimal inflation pressure: a new approach for pneumatic tourniquet application in upper limb surgery.

Anesth Analg

*Department of Anesthesiology and Reanimation, Dokuz Eylul University, and the †Department of Orthopaedics and Traumatology-Division of Hand Surgery, Dokuz Eylul University, İzmir, Turkey.

Published: November 2003

Unlabelled: Minimal inflation pressures are recommended for limb surgery to eliminate complications attributable to high inflation pressures with the pneumatic tourniquets. We applied controlled hypotension and a minimal inflation pressure (CHAMIP) technique to provide a bloodless surgical field. Thirty-six patients scheduled for upper extremity surgery were randomized equally to receive either normotensive anesthesia and conventional inflation pressures or controlled hypotension (systolic arterial blood pressure of 80-100 mm Hg and mean arterial blood pressure >60 mm Hg) and minimum inflation pressures. Anesthesia was induced with propofol IV bolus and remifentanil IV continuous infusion and maintained with propofol and remifentanil IV continuous infusion. To determine the minimal inflation pressure, the digital plethysmograph was applied to the second finger at the side of the operation and the tourniquet was inflated slowly until the arterial pulsations disappeared on the oscilloscope. A bloodless surgical field was obtained in almost all patients, even though systolic arterial blood pressures (100-138 mm Hg versus 80-100 mm Hg) and applied tourniquet inflation pressures (270 mm Hg versus 110-140 mm Hg) were significantly lower in the hypotensive group. No complications associated with controlled hypotension were encountered. In conclusion, CHAMIP may be a safe and reliable method for upper extremity surgery performed with pneumatic tourniquets.

Implications: Pneumatic tourniquets are associated with adverse effects resulting from high inflation pressures. Therefore, minimal inflation pressures are recommended in extremity surgery. To reach real minimal inflation pressure the patient's blood pressure must be reduced. We used controlled hypotension with remifentanil and propofol to reach minimal inflation pressures.

Download full-text PDF

Source
http://dx.doi.org/10.1213/01.ANE.0000081660.97731.91DOI Listing

Publication Analysis

Top Keywords

inflation pressures
32
minimal inflation
28
controlled hypotension
20
inflation pressure
16
inflation
12
extremity surgery
12
arterial blood
12
blood pressure
12
pressures
9
hypotension minimal
8

Similar Publications

Hypertension constitutes a significant risk factor for the development of many coronary artery diseases. In recent years, the advancement of technology and artificial intelligence has led to significant research and breakthroughs in wearable devices that can monitor blood pressure (BP). These devices offer continuous, real-time BP readings, facilitating the early detection and prevention of hypertension.

View Article and Find Full Text PDF

Background: Considerable morbidity is attributable to inappropriate tracheal cuff pressure. An earlier study undertaken in our hospital revealed that a normal cuff pressure of 20-30 cm HO was achieved in only 6% of intubated patients using subjective estimation methods.

Objective: To determine whether a training intervention could improve the accuracy of the subjective estimation method in our tracheal cuff monitoring.

View Article and Find Full Text PDF

Acute Responses of Low-Load Resistance Exercise with Blood Flow Restriction.

J Funct Morphol Kinesiol

December 2024

Patriot Performance Laboratory, Frank Pettrone Center for Sports Performance, George Mason University, Fairfax, VA 22030, USA.

Blood flow restriction (BFR) is a popular resistance exercise technique purported to increase metabolic stress and augment training adaptations over time. However, short-term use may lead to acute neuromuscular fatigue and higher exertion ratings. The purpose of the current study was to examine acute physiological responses to low-load resistance exercise utilizing BFR compared to higher-load, non-BFR resistance exercise.

View Article and Find Full Text PDF

Background: The Magenta Elevate is a 9-F, self-expanding, catheter-mounted pump delivered sheathed through a commercially available 10-F femoral introducer over the wire to the left ventricle (LV), providing temporary hemodynamic support up to an equivalent of normal cardiac output.

Objectives: The authors sought to assess the feasibility and outcomes of Elevate-supported high-risk percutaneous coronary intervention (HR-PCI) in a first-in-human study and study the hemodynamic impact of high-output support during prolonged interventional left main coronary artery (LM) occlusions.

Methods: In this study, 14 patients underwent Elevate-supported HR-PCI, with 8 patients undergoing 20 prolonged (39 ± 16 seconds) balloon occlusions of an unprotected LM.

View Article and Find Full Text PDF

Effectiveness of the repeated 3-time-balloon-inflation method in reducing coronary stent edge dissection.

Heart Vessels

December 2024

Division of Cardiovascular Medicine and Endocrinology and Metabolism, Faculty of Medicine, Tottori University, 86 Nishicho, Yonago, Japan.

The optimal procedural protocol for coronary stent deployment remains undetermined. Post-dilation with a high-pressure balloon is often performed to optimize the stent expansion. However, high-pressure dilation also carries the potential risk of coronary artery injury.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!