Unlabelled: Conventional methods of cardiac output monitoring using pulmonary artery catheters may not be feasible in patients with congenital heart disease because of patients' small size or aberrant anatomy. We studied the accuracy of a new device, which uses pulse contour analysis to measure continuous cardiac output, in children and adults undergoing congenital heart surgery. Sixteen patients, median ages 7 yr old, were included in this prospective study. One-hundred-ninety-one data points were obtained in the pre- and postcardiopulmonary bypass periods and in the first 12 h after intensive care unit admission. We evaluated the relationship between cardiac index (CI) derived from transpulmonary thermodilution (TDCI) and CI derived from pulse contour analysis (PCCI). Bias and limits of agreement between TDCI and PCCI over all time periods were 0.1 +/- 1.94, indicating a wide dispersion of the data. Coefficient of correlation (r) between the TDCI and PCCI was 0.7. Although in previous studies, PCCI has been suggested to be accurate in adult cardiac surgery, we found it to be less reliable in our study patients, even after shunt correction. The relationships of the volume and pressure based measures of preload, intrathoracic blood volume index (ITBI), and central venous pressure with CI were also investigated. After repair, correlation (r) between PCCI or TDCI and ITBI (0.56 and 0.71, respectively) was better than that between PCCI or TDCI and CVP (0.16 and 0.11, respectively), indicating greater validity of ITBI as a measure of preload.

Implications: Our results suggest that the pulse contour analysis cardiac output (CO) monitoring in patients undergoing congenital heart surgery may not provide as accurate or reliable measures of CO as previously suggested. The volume-based variable of preload intrathoracic blood volume index (ITBI) has better correlation with cardiac index (CI) than the central venous pressure, suggesting that ITBI may be a better indicator of preload.

Download full-text PDF

Source
http://dx.doi.org/10.1213/01.ANE.0000081797.61469.12DOI Listing

Publication Analysis

Top Keywords

pulse contour
16
contour analysis
16
cardiac output
16
congenital heart
16
output monitoring
12
cardiac
8
analysis cardiac
8
cardiac surgery
8
heart disease
8
undergoing congenital
8

Similar Publications

Background: Goal-directed haemodynamic therapy (GDHT) aims to optimize haemodynamic variables. However, its effectiveness in reducing postoperative complications in major abdominal surgery, particularly when targeting both arterial pressure and flow variables, remains unclear. This meta-analysis addresses this by evaluating GDHT using uncalibrated pulse contour (uPC) methods.

View Article and Find Full Text PDF

The Pulse Index Contour Continuous Cardiac Output (PICCO) module provides advanced and continuous monitoring of cardiac output through the use of arterial pulse contour analysis and transpulmonary thermodilution. The objective of this study was to compare the early postoperative outcomes of patients who were monitored using the conventional method and the pulse contour analysis method. A prospective observational study was conducted involving 45 patients who underwent cardiac surgery between 2020 and 2022.

View Article and Find Full Text PDF

AutoFOX: An automated cross-modal 3D fusion framework of coronary X-ray angiography and OCT.

Med Image Anal

December 2024

School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China; Department of Cardiovascular Medicine, University of Oxford, OX39DU, UK. Electronic address:

Article Synopsis
  • Coronary artery disease (CAD) is a major global health issue, and combining coronary X-ray angiography (XA) with optical coherence tomography (OCT) can enhance diagnosis and treatment by providing detailed images of coronary anatomy and plaque structure.
  • The new framework, AutoFOX, employs a deep learning model called TransCAN to accurately align 3D vascular images, achieving impressive alignment precision, especially at critical anatomical points.
  • AutoFOX also includes innovative methods for reconstructing side branches and utilizes a diverse dataset for validation, demonstrating strong accuracy and reliability in assessing bifurcation lesions, which is essential for improving CAD management and procedures.
View Article and Find Full Text PDF

To assess the impact of microgravity exposure on ocular rigidity (OR), intraocular pressure (IOP), and ocular pulse amplitude (OPA) following long-term space missions. OR was evaluated using optical coherence tomography (OCT) and deep learning-based choroid segmentation. IOP and OPA were measured with the PASCAL Dynamic Contour Tonometer (DCT).

View Article and Find Full Text PDF

Electrocardiograms (ECGs) can be affected by various factors and technical problems. It is rare for an artefact to be the cause of ST-segment elevation, especially in asymptomatic patients. An important distinction between true ST segment elevation caused by myocardial infarction and an artefact is that the baseline elevation in an artefact may begin before or after the appearance of the QRS complex.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!