Radiometrically accurate scene-based nonuniformity correction for array sensors.

J Opt Soc Am A Opt Image Sci Vis

Department of Electrical and Computer Engineering, The University of New Mexico, Albuquerque, New Mexico 87131-1356, USA.

Published: October 2003

AI Article Synopsis

Article Abstract

A novel radiometrically accurate scene-based nonuniformity correction (NUC) algorithm is described. The technique combines absolute calibration with a recently reported algebraic scene-based NUC algorithm. The technique is based on the following principle: First, detectors that are along the perimeter of the focal-plane array are absolutely calibrated; then the calibration is transported to the remaining uncalibrated interior detectors through the application of the algebraic scene-based algorithm, which utilizes pairs of image frames exhibiting arbitrary global motion. The key advantage of this technique is that it can obtain radiometric accuracy during NUC without disrupting camera operation. Accurate estimates of the bias nonuniformity can be achieved with relatively few frames, which can be fewer than ten frame pairs. Advantages of this technique are discussed, and a thorough performance analysis is presented with use of simulated and real infrared imagery.

Download full-text PDF

Source
http://dx.doi.org/10.1364/josaa.20.001890DOI Listing

Publication Analysis

Top Keywords

radiometrically accurate
8
accurate scene-based
8
scene-based nonuniformity
8
nonuniformity correction
8
nuc algorithm
8
algebraic scene-based
8
scene-based
4
correction array
4
array sensors
4
sensors novel
4

Similar Publications

A Comparative Review of the SWEET Simulator: Theoretical Verification Against Other Simulators.

J Imaging

November 2024

Cerema, Research Team "Intelligent Transport Systems", 8-10 Rue Bernard Palissy, CEDEX 2, F-63017 Clermont-Ferrand, France.

Accurate luminance-based image generation is critical in physically based simulations, as even minor inaccuracies in radiative transfer calculations can introduce noise or artifacts, adversely affecting image quality. The radiative transfer simulator, SWEET, uses a backward Monte Carlo approach, and its performance is analyzed alongside other simulators to assess how Monte Carlo-induced biases vary with parameters like optical thickness and medium anisotropy. This work details the advancements made to SWEET since the previous publication, with a specific focus on a more comprehensive comparison with other simulators such as Mitsuba.

View Article and Find Full Text PDF

Background And Objective: Chiari I Malformation-associated syringomyelia (CM) and idiopathic syringomyelia (IS) are often confused together. They require different diagnostic approach and treatment modalities; it is important to distinguish between the two. We aimed to evaluate the radiological and morphologic characteristics of CM and IS in adult and pediatric patients in Pakistani population.

View Article and Find Full Text PDF

Hydrazine, a compound recognized for its carcinogenic and genotoxic properties, presents a significant threat to human health via environmental exposure and drug metabolism. The detection of hydrazine is essential for safeguarding human health. However, a tool capable of accurately detecting hydrazine across diverse sample types, such as soil, water sources, and plant specimens contaminated by hydrazine leakage, as well as cells and live mice containing endogenously generated hydrazine from drug metabolism, is still lacking.

View Article and Find Full Text PDF

The X-Ray Sensor (XRS) has been making full-disk observations of the solar soft X-ray irradiance onboard National Oceanic and Atmospheric Administration's (NOAA) Geostationary Operational Environmental Satellites since 1975. Critical information about solar activity for space weather operations is provided by XRS measurements, such as the classification of solar flare magnitude based on X-ray irradiance level. The GOES-R series of XRS sensors, with the first in the series launched in November 2016, has a completely different instrument design compared to its predecessors, GOES-1 through GOES-15.

View Article and Find Full Text PDF

Design of a Bioluminescent Assay Platform for Quantitative Measurement of Histone Acetyltransferase Enzymatic Activity.

Chembiochem

January 2025

Department of Pharmaceutical and Biomedical Sciences, University of Georgia, Athens, Georgia, 30602, U.S.A.

Protein acetylation and acylation are widespread post-translational modifications (PTMs) in eukaryotic and prokaryotic organisms. Histone acetyltransferase (HATs) enzymes catalyze the addition of short-chain acyl moieties to lysine residues on cellular proteins. Many HAT members are found to be dysregulated in human diseases, especially oncological processes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!