The aim of this study was to obtain a quantitative analysis of the film thickness of a root canal sealer formed after filling by three different techniques. Thirty human maxillary incisors were selected and access cavities were prepared using high-speed diamond stones and water spray. A size #15 K-Flexofile was introduced in the canal of each specimen until it was seen just at the apical foramen. The working length was determined to be 1 mm short of that position and the canals were prepared to an apical size of #45 K-Flexofile. Copious irrigation with 5.25% NaOCl (sodium hypochlorite) was used during and after instrumentation. The samples were divided into three groups and obturated as follows: G1 - lateral condensation, G2 - lateral condensation with an accessory cone, and G3 - continuous wave of condensation. The samples were evaluated in the cervical, middle and apical thirds. The film thickness of the root canal sealer was measured through a microscopic evaluation. Statistical analysis was obtained using the Wilcox test. Statistical analysis showed significant differences between G3 and G1, G3 and G2 (p < 0.05). In general, the lowest film thickness was observed in the continuous wave of condensation (G3). Lateral condensation with an accessory cone (G2) and lateral condensation (G1) demonstrated poorer results in this study, showing a higher film thickness. The small film thickness of the sealer obtained by the continuous wave of condensation technique may increase the clinical performance of this technique.

Download full-text PDF

Source
http://dx.doi.org/10.1590/s1517-74912003000200004DOI Listing

Publication Analysis

Top Keywords

film thickness
24
lateral condensation
16
thickness root
12
root canal
12
canal sealer
12
continuous wave
12
wave condensation
12
analysis film
8
condensation lateral
8
condensation accessory
8

Similar Publications

Vanadium dioxide ([Formula: see text]) is a favorable material platform of modern optoelectronics, since it manifests the reversible temperature-induced insulator-metal transition (IMT) with an abrupt and rapid changes in the conductivity and optical properties. It makes possible applications of such a phase-change material in the ultra-fast optoelectronics and terahertz (THz) technology. Despite the considerable interest to this material, data on its broadband electrodynamic response in different states are still missing in the literature.

View Article and Find Full Text PDF

Low Temperature Atomic Layer Deposition of (00l)-Oriented Elemental Bismuth.

Angew Chem Int Ed Engl

January 2025

Leibniz-Institut fur Festkorper- und Werkstoffforschung Dresden eV, Helmholtzstraße 20, 01069, Dresden, GERMANY.

This study presents the first successful demonstration of growing elemental bismuth (Bi) thin films via thermal atomic layer deposition (ALD) using Bi(NMe2)3 as the precursor and Sb(SiMe3)3 as the co-reactant. The films were deposited at a relatively low temperature of 100 °C, with a growth per cycle (GPC) of 0.31-0.

View Article and Find Full Text PDF

Enhancing the ferroelectric performance of HfZrOfilms by optimizing the incorporation of Al dopant.

Nanotechnology

January 2025

School of Electrical Engineering, State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xianning West Road No.28 Xi'an Shannxi Province, Xi'an, Shaanxi, 710049, CHINA.

HfO-based ferroelectric (FE) thin films have gained considerable interest for memory applications due to their excellent properties. However, HfO₂-based FE films face significant reliability challenges, especially the wake-up and fatigue effects, which hinder their practical application. In this work, we fabricated 13.

View Article and Find Full Text PDF

An Au-Ag@Au fiber surface plasmon resonance sensor for highly sensitive detection of fluoroquinolone residues.

Analyst

January 2025

Tianjin Key Laboratory for Marine Environmental Research and Service, School of Marine Science and Technology, Tianjin University, Tianjin 300072, PR China.

Antibiotic residue detection plays an important role in protecting human health, but real-time, rapid, and highly sensitive detection is still challenging. Herein, gold and silver nanoparticles (Au-Ag NPs) were grown on the surface of optical fibers and a 50 nm thick gold film was deposited on the sensor's surface to fabricate the Au-Ag@Au fiber SPR sensor. The sensitivity of the sensor reached 3512 nm per RIU in the refractive index range of 1.

View Article and Find Full Text PDF

Aim: This study aimed to develop and evaluate lornoxicam (LXM) and thiocolchicoside (TCS) transferosomal transdermal patches.

Background: Oral administration of LXM and TCS can lead to gastric irritation, necessitating alternative delivery methods for pain and inflammation relief. Incorporating LXM & TCS into transferosomes within a transdermal patch offers a potential solution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!