A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Magnetic bead hybridization to detect enterotoxigenic Escherichia coli strains associated with cattle in environmental water sources. | LitMetric

A magnetic capture hybridization - polymerase chain reaction (MCH-PCR) method was used to increase the detection sensitivity of the enterotoxin gene LTIIa, used as a biomarker for waste in environmental samples. The samples were collected from cow lagoons of different farms and from environmental waters. Total DNA was extracted from colonies grown on mTEC medium or directly from environmental samples. The cow-specific Escherichia coli LTIIa gene was used as a DNA marker. A LTIIa-specific oligonucleotide probe was designed to capture the LTIIa marker during the MCH, followed by PCR. Varying levels of humic acid were added to the DNA extracts to evaluate the sensitivity and effectiveness of MCH-PCR. The minimal detection limit of MCH-PCR for the LTIIa gene was 2.5 ag/muL DNA. In the presence of humic acid, MCH-PCR was able to increase the detection sensitivity 10 000-fold over that of conventional PCR. The MCH-PCR could also detect one cell with the LTIIa DNA marker in a 1-L seeded environmental water sample. Results in this study indicate that MCH-PCR is more sensitive than nested PCR in testing environmental samples.

Download full-text PDF

Source
http://dx.doi.org/10.1139/w03-048DOI Listing

Publication Analysis

Top Keywords

environmental samples
12
escherichia coli
8
environmental water
8
increase detection
8
detection sensitivity
8
ltiia gene
8
dna marker
8
humic acid
8
environmental
6
mch-pcr
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!