Both microRNAs (miRNA) and small interfering RNAs (siRNA) share a common set of cellular proteins (Dicer and the RNA-induced silencing complex [RISC]) to elicit RNA interference. In the following work, a statistical analysis of the internal stability of published miRNA sequences in the context of miRNA precursor hairpins revealed enhanced flexibility of miRNA precursors, especially at the 5'-anti-sense (AS) terminal base pair. The same trend was observed in siRNA, with functional duplexes displaying a lower internal stability (Delta0.5 kcal/mol) at the 5'-AS end than nonfunctional duplexes. Average internal stability of siRNA molecules retrieved from plant cells after introduction of long RNA sequences also shows this characteristic thermodynamic signature. Together, these results suggest that the thermodynamic properties of siRNA play a critical role in determining the molecule's function and longevity, possibly biasing the steps involved in duplex unwinding and strand retention by RISC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0092-8674(03)00801-8 | DOI Listing |
Medicine (Baltimore)
January 2025
Second Hospital of the Air Force Medical University, Xi 'an, China.
Background: This study investigates the therapeutic efficacy of dynamic neuromuscular stabilization (DNS) technology paired with Kinesio Taping in patients with persistent nonspecific low back pain, as well as the effect on neuromuscular function and pain self-efficacy.
Methods: A randomized controlled clinical study was conducted to collect clinical data on DNS combined with KT for the treatment of chronic nonspecific low back pain from November 2023 to April 2024. The inclusion criteria were patients with chronic nonspecific lower back pain, aged between 18 and 30 years old, and without serious underlying medical conditions, such as cardiac disease, hypertension, and diabetes.
JBJS Case Connect
January 2025
Department of Orthopaedic Surgery, Nemours Children's Health, Wilmington, Delaware.
Case: A 14-year-old adolescent girl sustained a Lisfranc fracture-dislocation with an interposed extensor hallucis brevis (EHB) tendon. Following multiple failed attempts at closed reduction in both the emergency department and the operating room, the patient was treated in a staged manner with temporizing closed reduction and percutaneous pinning in improved alignment, followed by definitive open reduction and internal fixation once soft tissues allowed.
Conclusions: Anatomic reduction and stable fixation of Lisfranc injuries is vital to regain stability and reduce the risk of midfoot arthritis and collapse.
Sci Adv
January 2025
Department of Internal Medicine, University of Iowa Carver College of Medicine, Iowa City, IA, USA.
Oxygen controls most metazoan metabolism, yet in mammals, tissue O levels vary widely. While extensive research has explored cellular responses to hypoxia, understanding how cells respond to physiologically high O levels remains uncertain. To address this problem, we investigated respiratory epithelia as their contact with air exposes them to some of the highest O levels in the body.
View Article and Find Full Text PDFASAIO J
January 2025
Division of Cardiovascular Medicine, Department of Medicine, Stanford University School of Medicine, Palo Alto, California.
The use of an alteplase (Activase) purge solution to address Impella ventricular assist device "thrombosis" or "purge system occlusion" has been mainly documented with earlier generation Impella devices (CP, 2.5, 5.0).
View Article and Find Full Text PDFArch Orthop Trauma Surg
January 2025
Department of Orthopaedics, Wright State University, 30 E Apple St., Suite 2200, Dayton, OH, 45409, USA.
Introduction: We propose and assess the biomechanical stability of medial column screw supplementation in a synthetic distal femur fracture model.
Materials And Methods: Twenty-four low density synthetic femora modeling osteoporotic, intraarticular distal femur fractures with medial metaphyseal comminution were split into two fixation groups: (1) lateral locking distal femur plate (PA- plate alone) and (2) lateral locking distal femur plate with a 6.5 mm fully threaded medial cannulated screw (PWS- plate with screw).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!