Thirty-two patients with an ACL-deficient knee and lower limb varus alignment and 16 healthy controls were analyzed during level walking using a force-plate and optoelectronic system. The forces and moments of the lower limb and knee joint were measured and knee joint loads and ligament tensile forces were calculated using a mathematical model. The majority of patients (20 of 32) had an abnormally high adduction moment at the affected knee. The adduction moment showed a statistically significant correlation to high medial tibiofemoral compartment loads and high lateral soft tissue forces, but not to the degree of varus alignment on standing roentgenograms. Fifteen of 32 knees had abnormally high lateral soft tissue forces. We interpreted these gait findings as indicative of a medial shift in the center of maximal joint pressure and an increase in lateral soft tissue forces to achieve coronal plane stability. Further, there is the likelihood of separation of the lateral tibiofemoral joint and "condylar lift-off" during periods of the stance phase. If this occurs, all of the load-bearing forces would shift to the medial tibiofemoral joint and relatively large tensile forces would occur in the lateral soft tissue restraints. The flexion moment, as related to the quadriceps muscle force, was significantly lower than the control knees in 40% of the involved knees, and the extension moment, as related to the hamstring muscle force, was significantly higher in 50% of the involved knees. We interpret this finding as a gait adaptation tending to diminish quadriceps muscle activity and enhance hamstring muscle activity to provide dynamic anteroposterior stability of the knee joint. The fundamental assumption of this paper is that any combination of conditions leading to higher medial joint forces is associated with factors leading to more rapid degeneration of the medial compartment in patients with ACL deficiency, varus deformity, and lax lateral ligaments.

Download full-text PDF

Source
http://dx.doi.org/10.1177/036354659202000612DOI Listing

Publication Analysis

Top Keywords

lateral soft
16
soft tissue
16
varus alignment
12
knee joint
12
tissue forces
12
joint
8
lower limb
8
forces
8
tensile forces
8
abnormally high
8

Similar Publications

Supracondylar humerus fractures comprise of a major part in pediatric trauma cases. They result from a fall on an outstretched hand. The rotational components of Gartland type III fractures if not corrected appropriately can lead to cubitus varus (gun stock deformity).

View Article and Find Full Text PDF

Battery-free head orientation measurement using passive RFID tags.

Wearable Technol

February 2025

Department of Human Centered Design, Cornell University, Ithaca, NY, USA.

Real-time measurement of head rotation, a primary human body movement, offers potential advantages in rehabilitating head or neck motor disorders, promoting seamless human-robot interaction, and tracking the lateral glance of children with autism spectrum disorder for effective intervention. However, existing options such as cameras capturing the entire face or skin-attached sensors have limitations concerning privacy, safety, and/or usability. This research introduces a novel method that employs a battery-free RFID tag-based wearable sensor for monitoring head orientation, as a substitute for the existing options like camera.

View Article and Find Full Text PDF

Hibernomas are infrequent brown adipose tissue neoplasms. The thighs, shoulder, neck, and back are the most common places they appear. These are benign lipomatous neoplasms.

View Article and Find Full Text PDF

Understanding the deformation mechanism and behaviour of adjacent tunnels subjected to dynamic train loads provides vital technical insights for engineering design. This study conducted a detailed analysis and revealed that tunnel excavation significantly affects the stability of adjacent existing tunnels under dynamic loads. First, we developed a dynamic load simulation approach and derived a calculation formula for shield-soil friction.

View Article and Find Full Text PDF

Designing biomimetic substrates and electrodes for bioelectronic devices with the necessary mechanical, electrical, and biological properties is critical considering the potential mismatch between soft tissue and rigid electronics, where incompatibility leads to decreased device performance, delamination, inflammation, and discomfort. There is an unmet engineering and clinical need for epidermal bioelectronics that are bioinert, can emulate host tissue mechanical properties, demonstrate low bulk resistivity, and are flexible and scalable. To address this shortcoming, this work describes innovations pertaining to the development of a hydrophilic, biocompatible nanocomposite comprised of carbon black (CB), polyvinyl alcohol (PVA), and glycerol for neuro-muscular and rehabilitative applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!