A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The influence of a clear layer on near infrared spectrophotometry: comparison of measurements in a liquid neonatal head phantom to infants in vivo. | LitMetric

Near infrared spectrophotometric (NIRS) algorithms to determine the tissue oxygen saturation (TOI) assume a semi-infinite, homogenous tissue geometry. At the head, the clear cerebrospinal fluid (CSF) layer may violate this assumption. The aim was to estimate the error in the TOI values caused by the CSF layer in vitro and to confirm the results in vivo. The liquid phantom mimicking the neonatal head, consisted of a spherical shell of silicone filled with a liquid solution (1% Intralipid, 60 mumol/l haemoglobin, yeast) and a clear layer imitating CSF. The solution was oxygenated and deoxygenated, while measuring its TOI and pO2. Without clear layer the mean TOI was 90.9 +/- 0.5% at pO2 > 18 kPa and decreased to 26.0 +/- 1.3% at pO2 = 0 kPa. With a clear layer the TOI increased from 27.8 +/- 0.8% at pO2 > 18 kPa to 68.0 +/- 0.8% at pO2 = 0 kPa. The clear layer caused a large error in the TOI. In ten mechanically ventilated infants (postnatal age 0.03 to 8 months) the TOI (at the head) and arterial oxygen saturation (SaO2) were measured while the inspired oxygen fraction was altered. The TOI was always positively correlated with the SaO2 (mean slope linear regression = 0.89, r2 = 0.62). Thus an adverse effect of the CSF layer on TOI measurements can be excluded for infants. The CSF layer is not modelled correctly in the phantom.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-1-4615-0075-9_8DOI Listing

Publication Analysis

Top Keywords

clear layer
20
csf layer
16
po2 kpa
16
layer toi
12
layer
9
toi
9
neonatal head
8
oxygen saturation
8
error toi
8
kpa clear
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!