Temporary partially-covered metal stent insertion in benign esophageal stricture.

World J Gastroenterol

Department of Radiology, Sixth People's Hospital, Shanghai Jiaotong University, Shanghai 200233, China.

Published: October 2003

Aim: To study the therapeutic efficacy of temporary partially-covered metal stent insertion on benign esophageal stricture.

Methods: Temporary partially-covered metal stent was inserted in 83 patients with benign esophageal stricture. All the patients had various dysphagia scores.

Results: Insertion of 85 temporary partially-covered metal stents was performed successfully in 83 patients with benign esophageal stricture and dysphagia was effectively remitted in all the 83 cases. The dysphagia score was 3.20+/-0.63 (mean+/-SD) and 0.68+/-0.31 before and after stent insertion, and 0.86+/-0.48 after stent removal. The mean diameter of the strictured esophageal lumen was 3.37+/-1.23 mm and 25.77+/-3.89 mm before and after stent insertion, and 16.15+/-2.96 mm after stent removal. Follow-up time was from 1 week to 96 months (mean 54.26+/-12.75 months). The complications were chest pain (n=37) after stent insertion, and bleeding (n=12) and reflux (n=13) after stent removal.

Conclusion: Temporary partially-covered metal stent insertion is one of the best methods for treatment of benign esophageal stricture.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4656498PMC
http://dx.doi.org/10.3748/wjg.v9.i10.2359DOI Listing

Publication Analysis

Top Keywords

stent insertion
24
temporary partially-covered
20
partially-covered metal
20
benign esophageal
20
metal stent
16
esophageal stricture
16
stent
10
insertion benign
8
patients benign
8
stent removal
8

Similar Publications

Trans-jugular intrahepatic portosystemic stent shunting benefits and limits.

World J Gastrointest Surg

January 2025

Department of Surgery, Gastroenterology and Digestive Endoscopy Unit, ASST Santi Paolo e Carlo, University of Milan, Milan 20142, Lombardy, Italy.

Trans-jugular intrahepatic portosystemic stent shunting (TIPSS) has been in use for many years with great results and many evolutions. The procedure essentially involves the insertion of a metal covert stent to create an Hepato-Hepatic portosystemic shunt. Over time, TIPSS has become the subject of many studies aimed at examining its clinical utility and evaluating the results of using TIPSS to manage complications related to portal hypertension.

View Article and Find Full Text PDF

Background And Aim: Stent placement for biliary drainage in patients with malignant hilar biliary obstruction (MHBO) has been a topic of long-standing debate, and the best approach remains controversial. Therefore, we aimed to evaluate the efficacy, safety, and removability of multi-hole fully covered self-expandable metal stents (MH-FCSEMSs) in a preclinical experiment using swine hilar bile duct obstruction (HBDO) models and to assess the feasibility and safety of stent placement in patients with MHBO.

Methods: Three minipigs underwent endoscopic retrograde cholangiopancreatography (ERCP)-guided endobiliary-radio frequency ablation (EB-RFA) to establish Bismuth type II hilar bile duct stenosis models.

View Article and Find Full Text PDF

The p48 MW HPC is a novel low-profile flow diverter covered by a hydrophilic polymer coating with antithrombogenic properties, which may reduce ischemic complications and enable a single antiplatelet therapy after insertion of the stent. In this single-center experience, we describe the efficacy of this device, focusing on the illustration of different therapeutic indications and the outcome in various clinical settings with regard to vessel anatomy, bleeding state, and aneurysm configuration. We retrospectively reviewed our database for all patients being treated with a p48 MW HPC flow diverter between February 2019 and July 2021.

View Article and Find Full Text PDF

Comparison of outcomes with and without intrastent placement during PMS surgery.

Sci Rep

January 2025

Department of Ophthalmology and Visual Science, Kochi Medical School, Kochi University, Kohasu, Oko-cho, Nankoku City, 783-8505, Kochi, Japan.

To assess the efficacy of using a nylon suture as a stent in the PreserFlo MicroShunt (PMS) lumen to prevent postoperative hypotony, 59 eyes that underwent PMS implantation with follow-up for > 6 months were analyzed. Patients were divided into no intrastenting (NST) and intrastenting (ST) groups, with the ST group subdivided into 9 - 0 nylon suture fully placed (9 F), 9 - 0 nylon suture placement in only half of the lumen (9 H), 10 - 0 nylon suture fully placed (10 F), and 10 - 0 nylon suture placement in only half of the lumen (10 H). The distribution was as follows: 23 eyes in the NST group, 10 in the 9 F group, 9 in the 9 H group, 11 in the 10 F group, and 6 in the 10 H group.

View Article and Find Full Text PDF

We report the case of a woman in her early 30 s who was diagnosed with Robert's uterus. She had been experiencing progressive dysmenorrhea for a decade and sought treatment for infertility at our hospital. Preoperative ultrasound imaging resulted in a misdiagnosis of a complete uterine septum with an accompanying ovarian cyst.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!