A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Temporary emergency cardiac pacing under continuous echocardiographic control. Feasibility and safety of the procedure without using fluoroscopy]. | LitMetric

Background: Cardiac pacing often turns out to be the only effective treatment of severe brady-arrhythmias. Several invasive and noninvasive temporary pacing procedures are known, whose application is sometimes difficult or time-consuming. An alternative temporary cardiac pacing procedure is described in this article, which is based on echocardiographic control.

Methods: Fifty-four nonconsecutive patients were studied; they all were needing urgent cardiac pacing. A first choice attempt to perform an ultrasound-guided temporary cardiac pacing, by using a right jugular venous approach, was done. The catheter pathway was monitored by means of echocardiography performed by another operator. All data concerning time of execution, pacing parameters, acute or chronic complications and the in situ time duration of the catheter without needing to be repositioned were obtained.

Results: Ultrasound-guided cardiac pacing was not feasible in 3 patients (6%), because of a high thoracic acoustic impedance or failing to perform right jugular venous catheterization. Mean execution time was 680 +/- 179 s. Echocardiographic monitoring was performed in 50 patients by a cardiologist, in 1 patient by a non-cardiologist physician, and in 3 patients by a nurse, who had been previously trained to keep the transducer in the right position. No serious complications occurred. On 4 occasions (8%) the catheter had to be repositioned during the following hours. On 25 occasions (46%) permanent cardiac pacing was finally performed.

Conclusions: Temporary ultrasound-guided cardiac pacing seems to be a safe and easy procedure; it can be performed in a broad range of clinical and logistic scenarios and does not require fluoroscopic monitoring. A limited number of human resources is needed, but technical skills in central venous catheterization are required. Further studies are needed to validate this procedure; however it shows several potential benefits as compared to the other temporary cardiac pacing techniques.

Download full-text PDF

Source

Publication Analysis

Top Keywords

cardiac pacing
36
temporary cardiac
12
pacing
11
cardiac
9
jugular venous
8
ultrasound-guided cardiac
8
venous catheterization
8
temporary
5
[temporary emergency
4
emergency cardiac
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!