A quantitative analysis of valgus torque on the ACL: a human cadaveric study.

J Orthop Res

Department of Orthopaedic Surgery, Musculoskeletal Research Center, University of Pittsburgh, Pittsburgh, PA 15213, USA.

Published: November 2003

The loads needed to elicit a positive pivot shift test in a knee with an anterior cruciate ligament (ACL) rupture have not been quantified. The coupled anterior tibial translation (ATT), coupled internal tibial rotation (ITR), and the in situ force in the ACL in response to a valgus torque, an inherent component of the pivot shift test, were measured in 10 human cadaveric knee specimens. Using a robotic/universal force-moment sensor testing system, valgus torques ranging from 0.0 to 10.0 Nm were applied in nine increments on the intact and ACL-deficient knee in flexion ranging from 0 degrees to 90 degrees. At 15 degrees of knee flexion, the coupled ATT and ITR were significantly increased in the ACL-deficient knee when compared to the intact knee. Coupled ATT increased a maximum of 291% (6.7 mm, p<0.05), while coupled ITR increased a maximum of 85% (5.1 degrees, p<0.05). At 30 degrees, the increases in coupled ATT and ITR were significant at valgus loads of 3.3 Nm and greater with a maximum increase in coupled ATT of 137% (6.3 mm, p<0.05) and a maximum increase in coupled ITR of 38% (3.6 degrees, p<0.05). At 45 degrees, coupled ATT increased significantly (maximum of 69%, 4.4 mm, p<0.05), but only at torques > or =6.7 Nm. The in situ force in the ACL was less than 20 N for all flexion angles when a torque between 3.3 and 5.0 Nm was applied. Low valgus torque elicited tibial subluxation in the ACL-deficient knee with low in situ ACL forces, similar to a positive pivot shift test. Thus, application of a valgus torque may be suitable to evaluate ACL-deficient and ACL-reconstructed knees, since subluxation can be achieved with minimal harm to the ACL graft. This work is important in understanding one load component needed for the pivot shift examination; further studies quantifying other load components are essential for better comprehension of the in vivo pivot shift examination.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0736-0266(03)00084-6DOI Listing

Publication Analysis

Top Keywords

valgus torque
8
human cadaveric
8
pivot shift
8
shift test
8
acl-deficient knee
8
knee flexion
8
degrees degrees
8
coupled att
8
knee
6
quantitative analysis
4

Similar Publications

Benefits of Using Functional Joint Coordinate Systems in In Vitro Knee Testing.

J Biomech Eng

January 2025

Department of Biomedical Engineering and Lerner Research Institute, Cleveland Clinic, 2111 E. 96th Street, Cleveland, OH 44106.

To measure knee joint kinematics, coordinate systems (CS) must be assigned to the tibia and femur. Functional CS have been shown to be more reproducible than Anatomical. This study aims to quantify the benefits of using Functional CS in in vitro testing.

View Article and Find Full Text PDF

Purpose: The medial collateral ligament (MCL), and posterior oblique ligament (POL) are the primary valgus stabilisers of the knee, and clinical examinations in grading valgus instability can be inherently subjective. Stress radiography of medial-sided knee injuries provides objective diagnosis and was analysed in this study. We hypothesised that (1) medial joint space opening would increase cutting the superficial MCL (sMCL), POL and anterior cruciate ligament (ACL); (2) isolated deep MCL (dMCL) injury would not increase medial joint space opening; (3) medial joint space opening would increase at higher flexion angles.

View Article and Find Full Text PDF

Objective: To investigate the protective effects of ankle braces in patients with functional ankle instability.

Methods: This retrospective study involved 30 participants recruited from January 2023 to December 2023 at School of Physical Education, Nanchang University. These participants were divided into an ankle brace group wearing braces and a control group without braces.

View Article and Find Full Text PDF

Meniscal forces and knee kinematics are affected by tibial slope modifying high tibial osteotomy.

Knee Surg Sports Traumatol Arthrosc

January 2025

Orthopaedic Robotics Laboratory, Departments of Bioengineering and Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.

Purpose: To quantify the effect of increasing the posterior tibial slope (PTS) on knee kinematics and the resultant medial and lateral meniscal forces.

Methods: In this controlled laboratory study, a 6 degrees of freedom (DOF) robotic testing system was used to apply external loading conditions to seven fresh-frozen human cadaveric knees: (1) 200-N axial compressive load, (2) 5-N m internal tibial +10-N m valgus torque and (3) 5-N m external tibial + 10-N m varus torque. Knee kinematics and the resultant medial and lateral meniscal forces were acquired for two PTS states: (1) native PTS and (2) increased PTS.

View Article and Find Full Text PDF

[Biomechanical study of screw implant angle in reconstruction of tibiofibular syndesmosis injury].

Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi

December 2024

Department of Orthopedics, the Affiliated Traditional Chinese Medicine Hospital, Southwest Medical University, Luzhou Sichuan, 646000, P. R. China.

Objective: To investigate ideal screw implant angle in reconstruction of tibiofibular syndesmosis injury by using a biomechanical test.

Methods: A total of 24 ankle specimens from adult cadavers were used as the tibiofibular syndesmosis injury model. According to the angle of screw placement, the tibiofibular syndesmosis injury models were randomly divided into groups A (0°), B (10°-15°), C (20°-25°), and D (30°-35°), and the screws were placed at a level 2 cm proximal to the ankle joint.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!