Level-set-based artery-vein separation in blood pool agent CE-MR angiograms.

IEEE Trans Med Imaging

University Medical Center, Image Sciences Institute, NL-3584 CX Utrecht, The Netherlands.

Published: October 2003

Blood pool agents (BPAs) for contrast-enhanced (CE) magnetic-resonance angiography (MRA) allow prolonged imaging times for higher contrast and resolution. Imaging is performed during the steady state when the contrast agent is distributed through the complete vascular system. However, simultaneous venous and arterial enhancement in this steady state hampers interpretation. In order to improve visualization of the arteries and veins from steady-state BPA data, a semiautomated method for artery-vein separation is presented. In this method, the central arterial axis and central venous axis are used as initializations for two surfaces that simultaneously evolve in order to capture the arterial and venous parts of the vasculature using the level-set framework. Since arteries and veins can be in close proximity of each other, leakage from the evolving arterial (venous) surface into the venous (arterial) part of the vasculature is inevitable. In these situations, voxels are labeled arterial or venous based on the arrival time of the respective surface. The evolution is steered by external forces related to feature images derived from the image data and by internal forces related to the geometry of the level sets. In this paper, the robustness and accuracy of three external forces (based on image intensity, image gradient, and vessel-enhancement filtering) and combinations of them are investigated and tested on seven patient datasets. To this end, results with the level-set-based segmentation are compared to the reference-standard manually obtained segmentations. Best results are achieved by applying a combination of intensity- and gradient-based forces and a smoothness constraint based on the curvature of the surface. By applying this combination to the seven datasets, it is shown that, with minimal user interaction, artery-vein separation for improved arterial and venous visualization in BPA CE-MRA can be achieved.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TMI.2003.817756DOI Listing

Publication Analysis

Top Keywords

arterial venous
16
artery-vein separation
12
blood pool
8
steady state
8
venous arterial
8
arteries veins
8
external forces
8
applying combination
8
venous
7
arterial
7

Similar Publications

We sought to evaluate the intracardiac morphology and associated cardiovascular anomalies in patients with double inlet right ventricle (DIRV) on multidetector CT angiography. A retrospective search of our departmental database was conducted from January 2014 to January 2023 to identify patients with a diagnosis of DIRV on CT angiography. The intracardiac anatomy and associated cardiovascular abnormalities were systematically evaluated.

View Article and Find Full Text PDF

Preservation of Liver Graft Using the Hypothermic Oxygenated Perfusion (HOPE) System: A single-center experience.

Transplant Proc

January 2025

BioBizkaia Research Health Institute, Barakaldo, Bizkaia, Spain; Hepatobiliary Surgery and Liver Transplantation Unit, Cruces University Hospital, Bilbao, Spain. Electronic address:

Introduction: The hypothermic oxygenated perfusion (HOPE) system has been developed to improve the quality of previously considered suboptimal liver grafts, reduce complications, and increase the number of available donors. The aim of this study is to evaluate the results since its implementation in the liver transplant (LT) program at our center.

Materials And Methods: We conducted a retrospective descriptive analysis of all LTs with HOPE from August 2022 to November 2023 with a minimum follow-up of 3 months.

View Article and Find Full Text PDF

Background: Pediatric patients with Eosinophilic Granulomatosis with Polyangiitis (EGPA) are at an increased risk of arterial and venous thromboembolism (AVTE). Although the exact mechanisms underlying AVTE remain unclear, eosinophils play a pivotal role in AVTE.

Main Body: Current guidelines lack evidence-based recommendations, particularly concerning anticoagulant and antiplatelet treatments for this condition.

View Article and Find Full Text PDF

Objective: To evaluate the added value of dynamic contrast-enhanced ultrasound (DCE-US) analysis in pre-operative differential diagnosis of small (≤20 mm) solid pancreatic lesions (SPLs).

Methods: In this retrospective study, patients with biopsy or surgerical resection and histopathologically confirmed small (≤20 mm) SPLs were included. One wk before biopsy/surgery, pre-operative B-mode ultrasound and contrast-enhanced ultrasound were performed.

View Article and Find Full Text PDF

Spatially dependent tissue distribution of thyroid hormones by plasma thyroid hormone binding proteins.

Pflugers Arch

January 2025

Gangarosa Department of Environmental Health, Rollins School of Public Health, Emory University, Atlanta, GA, 30322, USA.

Plasma thyroid hormone (TH) binding proteins (THBPs), including thyroxine-binding globulin (TBG), transthyretin (TTR), and albumin (ALB), carry THs to extrathyroidal sites, where THs are unloaded locally and then taken up via membrane transporters into the tissue proper. The respective roles of THBPs in supplying THs for tissue uptake are not completely understood. To investigate this, we developed a spatial human physiologically based kinetic (PBK) model of THs, which produces several novel findings.

View Article and Find Full Text PDF