Purpose: The aim of this study was to create an animal model of endoleak after stent-graft placement for abdominal aortic aneurysm (AAA) in which a large aneurysmal sac would be preserved for the testing of techniques for its percutaneous occlusion.

Materials And Methods: Infrarenal AAAs were created in nine dogs by anastomosis of an isolated segment of the inferior vena cava to the right side of the abdominal aorta in combination with a large anterior patch from the external jugular vein. One hour later, animals underwent percutaneous implantation of polytetrafluoroethylene-covered Z stent endografts with three 3-mm-diameter holes through the fabric. Aortograms were obtained before and after surgery, after endograft placement, and at the time of animal sacrifice at 1 week or 1, 2, 3, or 6 months. Pressures within the aorta and the aneurysm sac were recorded before animal sacrifice. Gross and histologic evaluations of the specimens were then carried out.

Results: Immediately after endograft placement, all nine animals had artificial type III endoleaks with angiographic filling of lumbar arteries and veins. One animal died of surgical complications within 2 days of surgery and is not included in our data analysis. One aneurysm ruptured at 1 week. At completion of the study, six endografts were patent and two were occluded. The aneurysm sac had enlarged by approximately 50% in seven animals. At follow-up, type I endoleak was present in three animals, type II endoleak was present in three, and the artificial type III endoleak was present in all six animals with patent endografts. The pressure differential between aorta and aneurysm sac was 36 mm Hg, with a mean aortic pressure of 87 mm Hg +/- 13.3 and a mean aneurysmal sac pressure of 51 mm Hg +/- 28.1. The aneurysmal sac exhibited early thrombus formation at 1 week, which progressed to complete thrombosis in 1-6 months.

Conclusions: The model is technically feasible but would be useful in testing occlusive techniques for residual aneurysm sacs only in the acute phase after endograft placement. It would be not reliable for chronic evaluation because of rapidly progressive thrombosis in most aneurysm sacs and occasional complete thrombosis of the AAA and endograft.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.rvi.0000083256.29749.73DOI Listing

Publication Analysis

Top Keywords

aneurysmal sac
12
endograft placement
12
aneurysm sac
12
aneurysm
8
animal sacrifice
8
aorta aneurysm
8
artificial type
8
type iii
8
type endoleak
8
endoleak three
8

Similar Publications

Introduction: Abdominal aortic aneurysms (AAA) are major causes of morbidity and mortality in the elderly population. Endovascular aneurysm repair (EVAR) is associated with lower complications rates than conventional treatment; however, rigorous follow-up with contrast imaging is required to confirm aneurysmal sac exclusion. The main objective of this study was to quantify and evaluate miRNA expression response to EVAR based on serum dosages at the 6-month follow-up.

View Article and Find Full Text PDF

We investigated the association between brachial-ankle pulse wave velocity (PWV) and arterial stiffness and distensibility in the aneurysmal sac of abdominal aortic aneurysm (AAA). Data from 49 patients with AAA from June 2020 to November 2022 at Tokyo Medical University Hospital were retrospectively analyzed. Brachial-ankle PWV (cm/s) was obtained via an automated oscillometric method.

View Article and Find Full Text PDF

Adverse iliofemoral anatomy represents a unique challenge for endovascular aortic aneurysm repair (EVAR). This report describes a transaxillary EVAR in a patient with severe iliofemoral occlusive disease and an infrarenal aortic aneurysm. A reversely mounted Gore Excluder graft was advanced and deployed in the infrarenal aorta using the left axillary artery.

View Article and Find Full Text PDF

Objective: This study aimed to compare treatment outcomes between graft replacement and aneurysmorrhaphy with ligation of the aortic side branches for type 2 endoleaks after endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms.

Methods: We retrospectively analyzed multicenter data of patients who underwent open surgical conversion, including graft replacement or aneurysmorrhaphy with ligation of the aortic side branches (graft preservation) for the treatment of type 2 endoleaks between 2007 and 2022. The endpoints were postoperative complications, 30-day mortality, overall survival, and reintervention or sac expansion after open surgical conversion.

View Article and Find Full Text PDF

Is Sac Thrombus Good or Bad for Complex Endovascular Aneurysm Repair?

Eur J Vasc Endovasc Surg

January 2025

Vascular Unit, 5th Department of Surgery, Medical School, Aristotle University of Thessaloniki, Hippokratio Hospital, Thessaloniki, Greece. Electronic address:

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!