Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The monosyllable speech perception ability after years of educational intervention was compared between prelingually deafened pediatric hearing aid users and their cochlear implant counterparts.
Design: An open-set monosyllabic speech perception test was conducted on all subjects. The test required subjects to indicate a corresponding Japanese character to that spoken by the examiner. Fifty-two subjects with prelingual hearing impairment (47 hearing aid users and 5 cochlear implant users) were examined.
Results: Hearing aid users with average pure-tone thresholds less than 90 dB HL demonstrated generally better monosyllable perception than 70%, which was equivalent or better performance than that of the cochlear implant group. Widely dispersed speech perception was observed within the 90-99 dB HL hearing-aid user group with most subjects demonstrating less than 50% speech perception. In the cluster of >100 dB HL, few cases demonstrated more than 50% in speech perception. The perception ability of the vowel part of each mora within the cochlear implant group was 100% and corresponding to that of hearing aid users with moderate and severe hearing loss.
Conclusion: Hearing ability among cochlear implant users can be comparable with that of hearing aid users with average unaided pure-tone thresholds of 90 dB HL, after monosyllabic speech perception testing was performed.