Technology and the future of cochlear implants.

Ann Otol Rhinol Laryngol Suppl

Advanced Cochlear Systems, 34935 SE Douglas St, Suite 200, Snoqualmie, WA 98065, USA.

Published: September 2003

Cochlear implants are one of the dramatic success stories of the bioengineering enterprise. Although these prostheses are used extensively, they still can be improved substantially. We suggest that high-density electrode designs will permit field shaping and field steering to an extent not presently possible with the arrays that are used today. Those opportunities will make it possible to make use of the phase information that is richly available to normal listeners. Although this information makes possible more precise location of sound sources in the auditory environment, and will likely improve the recognition of intelligent sound in noise, it will require the consumption of additional power in future cochlear prostheses. Those opportunities and trade-offs provide the designers of cochlear implants with exciting goals for the future.

Download full-text PDF

Source
http://dx.doi.org/10.1177/00034894031120s906DOI Listing

Publication Analysis

Top Keywords

cochlear implants
12
future cochlear
8
technology future
4
cochlear
4
implants cochlear
4
implants dramatic
4
dramatic success
4
success stories
4
stories bioengineering
4
bioengineering enterprise
4

Similar Publications

EXPRESS: The Time Course of Cognitive Effort During Disrupted Speech.

Q J Exp Psychol (Hove)

January 2025

Hearing Aid Laboratory, Northwestern University, Department of Communication Sciences and Disorders Evanston, IL, USA.

Listeners often find themselves in scenarios where speech is disrupted, misperceived, or otherwise difficult to recognize. In these situations, many individuals report exerting additional effort to understand speech, even when repairing speech may be difficult or impossible. This investigation aimed to characterize cognitive effort across time during both sentence listening and a post-sentence retention interval by observing the pupillary response of participants with normal to borderline normal hearing in response to two interrupted speech conditions: sentences interrupted by gaps of silence or bursts of noise.

View Article and Find Full Text PDF

Can a Cochlear Implant Be Used as an Electrical Impedance Tomography Device?

Int J Numer Method Biomed Eng

January 2025

Bioengineering, Department of Electrical, Electronic and Computer Engineering, University of Pretoria, Gauteng, South Africa.

The imaging of the live cochlea is a challenging task. Regardless of the quality of images obtained from modern clinical imaging techniques, the internal structures of the cochlea mainly remain obscured. Electrical impedance tomography (EIT) is a safe, low-cost alternative medical imaging technique with applications in various clinical scenarios.

View Article and Find Full Text PDF

Objective: To provide evidence to use an extended frequency pure tone average to screen for cochlear implant evaluation candidates as recommended by the American Cochlear Implant Alliance. Additionally, to determine whether traditional low frequency, high or low frequency, high frequency, or extended frequency pure tone average most accurately predicts cochlear implant candidates based on speech perception scores from aided AzBio sentence testing or aided consonant-nucleus-consonant (CNC) testing.

Method: Adults from a tertiary care center who completed aided sentence testing during cochlear implant evaluation between 2014 and 2024 were assessed.

View Article and Find Full Text PDF

Background: This investigation quantifies the mean and median hearing thresholds and assesses the prevalence of age-related hearing loss within the senior population of Taipei.

Methods: In a substantive geriatric assessment supported by government initiative, 1696 individuals from a community hospital partook in this cross-sectional study (2016-2018). Detailed audiometric evaluations logged pure-tone thresholds across critical frequencies (0.

View Article and Find Full Text PDF

Objective: Measuring listening effort using pupillometry is challenging in cochlear implant (CI) users. We assess three validated speech tests (Matrix, LIST, and DIN) to identify the optimal speech material for measuring peak-pupil-dilation (PPD) in CI users as a function of signal-to-noise ratio (SNR).

Design: Speech tests were administered in quiet and two noisy conditions, namely at the speech recognition threshold (0 dB re SRT), i.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!