We have developed a method for fabricating microfluidic devices with multi-height structures using single step photolithography. The whole fabrication process is executed by conventional printed circuit board (PCB) technology without the need of having access to clean room facilities. Specifically designed "windows" and "rims" architectures were printed on films that were used as photomasks. Different levels of protruding features on the PCB master were produced by exposing a photomask followed by chemical wet etching. Poly(dimethylsiloxane) (PDMS) was then moulded against the positive relief master to generate microfluidic structures. In this report, we described the fabrication of a microfluidic device featured with a multi-height "sandbag" structure for particle entrapment and peripheral microchannels. Controlled immobilization of biological cells and immunocytochemcial staining assays were performed to demonstrate the applicability of the microfluidic device for cellular analysis. The integrity of the microdevice remained stable under applied pressure, indicating the robustness of the elastic PDMS structures for analytical operation. The simple microfabrication process requires only low-cost materials and minimal specialized equipment and can reproducibly produce mask lines of about 20 microm in width, which is sufficient for most microfluidic applications.

Download full-text PDF

Source
http://dx.doi.org/10.1039/b304354aDOI Listing

Publication Analysis

Top Keywords

microfluidic device
12
multi-height structures
8
printed circuit
8
circuit board
8
microfluidic
5
pdms-based microfluidic
4
device multi-height
4
structures
4
structures fabricated
4
fabricated single-step
4

Similar Publications

Portable sensor technologies are indispensable in personalized healthcare and environmental monitoring as they enable the continuous tracking of key analytes. Human sweat contains valuable physiological information, and previously developed noninvasive sweat-based sensors have effectively monitored single or multiple biomarkers. By successfully detecting biochemicals in sweat, portable sensors could also significantly broaden their application scope, encompassing non-biological fluids commonly encountered in daily life, such as mineral water.

View Article and Find Full Text PDF

We engineered a microfluidic platform to study the effects of bioactive glass nanoparticles (BGNs) on cell viability under static culture. We incorporated different concentrations of BGNs (1%, 2%, and 3% w/v) in collagen hydrogel (with a concentration of 3.0 mg/mL).

View Article and Find Full Text PDF

Developmental toxicity (DevTox) tests evaluate the adverse effects of chemical exposures on an organism's development. Although current testing primarily relies on large mammalian models, the emergence of new approach methodologies (NAMs) is encouraging industries and regulatory agencies to evaluate novel assays. C.

View Article and Find Full Text PDF

A microfluidics platform for simultaneous evaluation of sensitivity and side effects of anti-cancer drugs using a three-dimensional culture method.

Sci Rep

January 2025

Laboratory of Veterinary Pharmacology, Department of Veterinary Medicine, Faculty of Agriculture, Tokyo University of Agriculture and Technology, 3-5-8 Saiwai-cho, Fuchu , Tokyo, 183-8509, Japan.

Organoids are stem cell-derived three-dimensional tissue cultures composed of multiple cell types that recapitulate the morphology and functions of their in vivo counterparts. Organ-on-a-chip devices are tiny chips with interconnected wells and channels designed using a perfusion system and microfluidics to precisely mimic the in vivo physiology and mechanical forces experienced by cells in the body. These techniques have recently been used to reproduce the structure and function of organs in vitro and are expected to be promising alternatives for animal experiments in the future.

View Article and Find Full Text PDF

X-ray crystallography is one of the leading tools to analyze the 3-D structure, and therefore, function of proteins and other biological macromolecules. Traditional methods of mounting individual crystals for X-ray diffraction analysis can be tedious and result in damage to fragile protein crystals. Furthermore, the advent of multi-crystal and serial crystallography methods explicitly require the mounting of larger numbers of crystals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!