A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Application of a Ge semi-conductor detector to whole-body counter. | LitMetric

Application of a Ge semi-conductor detector to whole-body counter.

Radiat Prot Dosimetry

Japan Atomic Energy Research Institute, 2-4 Shirane, Shirakata, Tokai-mura, Ibaraki 319-1195, Japan.

Published: December 2003

To calibrate a whole-body counter, it is necessary to find a determination method for peak efficiencies of detectors used in the whole-body counter. For this purpose, peak efficiencies of a Ge semiconductor detector for point and volume sources were evaluated in the photon energy range 60-1836 keV by Monte Carlo simulation and experiment. It was found that the calculated peak efficiency curves as a function of energy without modelling of the actual sensitive region of the detector are similar in shape to those measured. The calculated peak efficiencies of the detector having an apparent dead layer (1 mm) were also found to agree with the experimental values (deviations from -10-24%). Consequently, the simulation method for peak efficiencies was validated. In addition, an optimum design for a whole-body counter with Ge semiconductor detectors was examined by simulation. This simulation provides a method to determine an optimum arrangement of detectors in a whole-body counter, offering a uniform response to various 137Cs distributions in a human body.

Download full-text PDF

Source
http://dx.doi.org/10.1093/oxfordjournals.rpd.a006283DOI Listing

Publication Analysis

Top Keywords

whole-body counter
20
peak efficiencies
16
method peak
8
detectors whole-body
8
calculated peak
8
simulation method
8
whole-body
5
counter
5
peak
5
application semi-conductor
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!