A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reproducibility of morphoscopic contrast sensitivity testing with the Visual Capacity Analyzer. | LitMetric

Purpose: To determine the reproducibility of morphoscopic contrast sensitivity test values in healthy subjects using the Visual Capacity Analyzer (VCA) (L2 Informatique).

Setting: Institute of Vision Research, Department of Ophthalmology, Yong-Dong Severance Hospital, Yonsei University, Seoul, South Korea.

Methods: Five healthy volunteers were recruited for this study. With the VCA, 1 eye of each person was tested with different sized letters displayed on a computer screen at 11 spatial frequencies ranging from low (3.0 cycles/deg [cpd]) to high (30.0 cpd). The measurement was repeated 5 times under 2 screen luminance levels (maximum and 3 cd/m2).

Results: Under maximum luminance background, the coefficient of variation (CV) and reliability coefficient (RC) at the spatial frequencies examined ranged from 4.3% to 35.0% and 89.1% to 99.8%, respectively. Under a screen luminance of 3 cd/m2, the CV ranged from 0.5% to 15.9% and the RC, from 97.5% to 100.0%.

Conclusion: At the spatial frequencies examined, morphoscopic contrast sensitivity testing using the VCA had a high level of reproducibility and may be useful in measuring a patient's visual function in the actual environment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0886-3350(03)00044-0DOI Listing

Publication Analysis

Top Keywords

morphoscopic contrast
12
contrast sensitivity
12
spatial frequencies
12
reproducibility morphoscopic
8
sensitivity testing
8
visual capacity
8
capacity analyzer
8
screen luminance
8
frequencies examined
8
testing visual
4