A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Three-dimensional visualization and morphometry of small airways from microfocal X-ray computed tomography. | LitMetric

Three-dimensional visualization and morphometry of small airways from microfocal X-ray computed tomography.

J Biomech

School of Fundamental Science and Technology, Center for Life Science and Technology, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan.

Published: November 2003

Physiological morphometry is a critical factor in the flow dynamics in small airways. In this study, we visualized and analyzed the three-dimensional structure of the small airways without dehydration and fixation. We developed a two-step method to visualize small airways in detail by staining the lung tissue with a radiopaque solution and then visualizing the tissue with a cone-beam microfocal X-ray computed tomographic (CT) system. To verify the applicability of this staining and CT imaging (SCT) method, we used the method to visualize small airways in excised rat lungs. By using the SCT method to obtain continuous CT images, three-dimensional branching and merging bronchi ranging from 500 to 150 microm (the airway generation=8-16) were successfully reconstructed. The morphometry of the small airways (diameter, length, branching angle and gravity angle between the gravity direction and airway vector) was analyzed using the three-dimensional thinning algorithm. The diameter and length exponentially decreased with the airway generation. The asymmetry of the bifurcation decreased with generation and one branching angle decided the other pair branching angle. The SCT method is the first reported method that yields faithful high-resolution images of soft tissue geometry without fixation and the three-dimensional morphometry of small airways is useful for studying the biomechanical dynamics in small airways.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0021-9290(03)00179-9DOI Listing

Publication Analysis

Top Keywords

small airways
32
morphometry small
12
sct method
12
branching angle
12
small
8
airways
8
microfocal x-ray
8
x-ray computed
8
dynamics small
8
analyzed three-dimensional
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!