OP-1 increases bone ingrowth distance of new bone into allografts (Tägil et al. 2000), but the bone density after incorporation may be reduced by an increase in resorption (Höistner et al. 2000). Bisphosphonates inactivate osteoclasts and can be used to increase allograft bone density after incorporation (Aspenberg and Astrand 2002). A combination of locally-applied bisphosphonate and OP-1 in the graft could therefore be expected to increase both new bone ingrowth and density. We tested this by using a rat bone chamber model. OP-1 alone increased the ingrowth distance of bone. Clodronate increased final bone density greatly, but reduced the ingrowth distance of new bone into grafts that were extremely impacted. This reduction was improved by adding OP-1. Regardless of graft density, combinations of OP-1 and clodronate included a high final bone density, but the ingrowth distances were shorter than with OP-1 alone. These data indicate that new bone and tissue ingrowth into a compacted graft depends on resorption and that resorption is a prerequisite for the stimulating effect of OP-1 in this experimental set-up. Although the problems associated with the use of OP-1 in impaction grafting may be solved by adding a bisphosphonate, some of the benefits of OP-1 can be lost.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00016470310017839DOI Listing

Publication Analysis

Top Keywords

bone density
16
bone
12
ingrowth distance
12
distance bone
12
op-1
9
bone allografts
8
bone ingrowth
8
density incorporation
8
op-1 graft
8
final bone
8

Similar Publications

Introduction: Bone marrow-derived mesenchymal stem cell-derived extracellular vesicles (BMSC-EVs) are widely used for therapeutic purposes in preclinical studies. However, their utility in treating diabetes-associated atherosclerosis remains largely unexplored. Here, we aimed to characterize BMSC-EV-mediated regulation of autophagy and macrophage polarization.

View Article and Find Full Text PDF

Sport participation affects body composition and bone health, but the association between sport, body composition, and bone health in female athletes is complex. We compared areal bone mineral density (aBMD, DXA) and tibial volumetric bone mineral density (vBMD), geometry, microarchitecture, and estimated strength (HR-pQCT) in cross-country runners (n = 22), gymnasts (n = 23) and lacrosse players (n = 35), and investigated associations of total body lean mass (TBLM), team, and their interaction with tibial bone outcomes. Total body (TB), total hip (TH), femoral neck (FN), and lumbar spine (LS) aBMD were higher in gymnasts than runners (p < 0.

View Article and Find Full Text PDF

This study examines the biocompatibility, osteogenic potential, and effectiveness of polyether ether ketone (PEEK) composites for treating osteonecrosis, seeking to establish a theoretical basis for clinical application. A range of PEEK composite materials, including sulfonated polyether ether ketone (SPEEK), polydopamine-sulfonated polyether ether ketone (SPEEK-PDA), bone-forming peptide-poly-dopamine-sulfonated polyether ether ketone (SPEEK-PDA-BFP), and vascular endothelial growth factor-poly-dopamine-sulfonated polyether ether ketone (SPEEK-PDA-VEGF), were constructed by concentrated sulfuric acid sulfonation, polydopamine modification and grafting of bioactive factors. The experiments involved adult male New Zealand rabbits aged 24-28 weeks and weighing 2.

View Article and Find Full Text PDF

The effect of bone relaxation on the simulated pull-off force of a cementless femoral knee implant.

J Biomech

January 2025

Radboudumc, Orthopaedic Research Lab, PO Box 9101, 6500 HB Nijmegen, the Netherlands.

Aseptic loosening is the primary cause of revision in cementless total knee arthroplasty (TKA), emphasizing the importance of strong initial stability for long-term implant success. Pre-clinical evaluations are crucial for understanding implant fixation mechanics and improving implant designs. Finite element (FE) analysis models often use linear elastic bone material models, which do not accurately reflect bone's mechanical behavior.

View Article and Find Full Text PDF

Background: Magnetic resonance imaging (MRI) has not been routinely used for infants with brachial plexus birth injury (BPBI); instead, the decision to operate is based on the trajectory of clinical recovery by 6 months of age. The aim of this study was to develop an MRI protocol that can be performed without sedation or contrast in order to identify infants who would benefit from surgery at an earlier age than the age at which that decision could be made clinically.

Methods: This prospective multicenter NAPTIME (Non-Anesthetized Plexus Technique for Infant MRI Evaluation) study included infants aged 28 to 120 days with BPBI from 3 tertiary care centers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!