Objective: The purpose of this study was to assess changes in menstrual pattern, quality of life, and patient satisfaction after thermal balloon ablation for abnormal uterine bleeding.
Study Design: One hundred forty-one women who underwent thermal balloon ablation in our institution initially had their charts reviewed for demographics, procedure data, clinical history, and follow-up. Thereafter, a telephone interview was conducted to assess postprocedural menstrual pattern, quality of life, and patient satisfaction. Data were compared with the use of appropriate tests for categoric or continuous variables and logistic regression.
Results: The median follow-up time was 18 months, and a telephone interview was obtained for 119 of 141 patients. A reduction in days per cycle (9.6 vs 3.1 days, P<.0001) and in pads per day (12.8 vs 2.5 pads/d, P<.0001) and an improvement in self-reported quality of life scores (2.8 vs 9.0, P<.0001) were observed after thermal balloon ablation. Hysterectomy was required in 21 of 141 patients (15%). Assessment of the level of satisfaction showed that 96% of patients were satisfied or very satisfied with the procedure. No major complications or deaths were related to thermal balloon ablation.
Conclusion: Thermal balloon ablation is a safe and efficient method to treat abnormal uterine bleeding. It reduces the menstrual flow, improves the quality of life, and remarkably fulfills expectations in selected patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1067/s0002-9378(03)00403-4 | DOI Listing |
Int J Mol Sci
December 2024
Pre-Clinical Research Centre, Wrocław Medical University, Marcinkowskiego 1, 50-368 Wrocław, Poland.
Percutaneous Coronary Intervention (PCI) is a treatment method that involves reopening narrowed arteries with a balloon catheter that delivers a cylindrical, mesh-shaped implant device to the site of the stenosis. Currently, by applying a coating to a bare metal stent (BMS) surface to improve biocompatibility, the main risks after PCI, such as restenosis and thrombosis, are reduced while maintaining the basic requirements for the mechanical behavior of the stent itself. In this work, for the first time, the development and optimization process of the spatial structure of the Co-Cr stent (L-605) with a graphene-based coating using cold-wall chemical vapor deposition (CW-CVD) to ensure uniform coverage of the implant was attempted.
View Article and Find Full Text PDFSensors (Basel)
November 2024
Institute for Applied Microelectronics (IUMA), University of Las Palmas de Gran Canaria (ULPGC), 35017 Las Palmas de Gran Canaria, Spain.
CubeSats have emerged as a promising alternative to satellite missions for studying remote areas where satellite data are scarce and insufficient, such as coastal and marine environments. However, their standard size and weight limitations make integrating remote sensing optical instruments challenging. This work presents the development of Bentayga-I, a CubeSat designed to validate PANDORA, a self-made, lightweight, cost-effective multispectral camera with interchangeable spectral optical filters, in near-space conditions.
View Article and Find Full Text PDFJA Clin Rep
November 2024
Department of Anesthesiology, Wakayama Medical University School of Medicine, Wakayama, 641-8510, Japan.
Background: Common causes of air leakage around an endotracheal tube include insufficient endotracheal tube cuff inflation and damage to the cuff, while damage to the pilot balloon or pilot balloon tubing is relatively rare.
Case Presentation: A 74-year-old female with vertebral osteomyelitis was scheduled for an extreme lateral interbody fusion followed posterior fixation. A fiber-optic light was utilized as part of the surgical illuminator.
J Interv Card Electrophysiol
November 2024
Cardioangiologisches Centrum Bethanien, Frankfurt am Main, Germany.
Background: A novel irrigated radiofrequency balloon (RFB) for pulmonary vein isolation (PVI) integrated into a 3D mapping platform was recently launched.
Methods: Patients undergoing a first atrial fibrillation (AF) ablation at two German high-volume EP centers were included into the prospective AURORA registry. All patients underwent clinical follow-up (FU) at 90, 180, and 360 days following ablation including 48-h Holter ECGs.
Hepatobiliary Pancreat Dis Int
October 2024
Department of Ultrasound Medicine, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China; Department of Hepatobiliary and Pancreatic Surgery, the First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou 310003, China. Electronic address:
Background: Balloon catheter isolation is a promising auxiliary method for thermal ablation treatment of liver cancer. We aimed to explore the safety and effectiveness of balloon catheter isolation-assisted ultrasound-guided percutaneous microwave ablation (MWA) in treating liver cancer in difficult anatomical locations.
Methods: Data of 132 patients with 145 difficult-site liver cancer treated with ultrasound-guided percutaneous MWA were retrospectively analyzed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!