There is increasing evidence for monitoring the bone trabecular structure to explain, in part, the mechanical properties of bone. Despite the emergence of Computed Tomography, a radiograph is the standard format as it is cheap and used for assessing implant performance. Furthermore, various image-processing techniques developed to assess the trabecular structure from radiographs have regained interest owing to improvements in imaging equipment. This study assessed the precision and accuracy of the Co-occurrence and Run-length matrix, Spatial-frequency and Minkowski-fractal techniques to infer the trabecular direction from radiographs. Ten clinical images of femoral neck regions were obtained from digitised pelvic radiographs and subsequently analysed. These data were also used to generate synthetic images where the trabecular thickness, separation and directions were controlled in order to calculate the accuracy of the techniques. Additionally, a Laplacian noise was added in order to infer the precision of the techniques. All methods assessed the trabecular direction with a high degree of accuracy in these synthetic images including a single direction and no noise. However, only the Spatial-frequency and Co-occurrence matrix methods performed well on the clinical and heavily corrupted synthetic images. This demonstrated the possibility of inferring a linear trabecular direction in clinical conditions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1350-4533(03)00123-1DOI Listing

Publication Analysis

Top Keywords

trabecular direction
12
synthetic images
12
trabecular structure
8
trabecular
6
direction
5
determination trabecular
4
trabecular bone
4
bone direction
4
direction digitised
4
radiographs
4

Similar Publications

Osteonecrosis of the femoral head (ONFH) is a prevalent orthopedic disorder characterized primarily by compromised blood supply. This vascular deficit results in cell apoptosis, trabecular bone loss, and structural collapse of the femoral head at late stage, significantly impairing joint function. While MRI is a highly effective tool for diagnosing ONFH in its early stages, challenges remain due to the limited availability and high cost of MRI, as well as the absence of routine MRI screening in asymptomatic patients.

View Article and Find Full Text PDF

Rebound bone loss following denosumab discontinuation is an important barrier in the effective long-term treatment of skeletal disorders. This is driven by increased osteoclastic bone resorption following the offset of RANKL inhibition, and sequential osteoclast-directed therapy has been utilised to mitigate this. However, current sequential treatment strategies intervene following the offset of RANKL inhibition and this approach fails to consistently prevent bone loss.

View Article and Find Full Text PDF

Persistent hypotony following Tanito microhook trabeculotomy (TMH) is rare but may occur due to the development of cyclodialysis clefts. We report a case of a Japanese man in his 40s who developed persistent hypotony and hypotony maculopathy after TMH in the left eye. Fourteen months after the surgery, the patient was referred to our institution due to prolonged hypotony that remained undiagnosed and untreated despite evaluations with gonioscopy and anterior segment optical coherence tomography (AS-OCT) at the referring clinic.

View Article and Find Full Text PDF

Tubulin Acetylation Enhances Microtubule Stability in Trabecular Meshwork Cells Under Mechanical Stress.

Invest Ophthalmol Vis Sci

January 2025

Department of Ophthalmology, Duke Eye Center, Duke University, Durham, North Carolina, United States.

Purpose: To study the roles of tubulin acetylation and cyclic mechanical stretch (CMS) in trabecular meshwork (TM) cells and their impact on outflow pathway physiology and pathology.

Methods: Primary TM cell cultures were subjected to CMS (8% elongation, 24 hours), and acetylated α-tubulin at lysine 40 (Ac-TUBA4) was assessed by western blotting and immunofluorescence. Enzymes regulating tubulin acetylation were identified via siRNA-mediated knockdowns of ATAT1, HDAC6, and SIRT2.

View Article and Find Full Text PDF

Medusa's gaze: Cell traces and fibrils but no collagen in permineralized Jurassic ichthyosaur bone.

iScience

January 2025

Abteilung Paläontologie, Bonner Institut für Organismische Biologie, Universität Bonn, 53115 Bonn, Germany.

Bone is formed by specialized cells whose activity allows bone to grow, change shape, and repair itself. Its composite structure of collagen fibrils and bioapatite nanocrystals gives bone exceptional mechanical strength. Using scanning electron microscopy, we show in fossil ichthyosaurs, 150 to 200 million years old, from the Jurassic of France and the UK, abundant and direct evidence of cellular activity on the fossilized forming, resting, and resorbing surfaces of bone trabeculae, as well as bone fibrils, Sharpey fibers, and cartilage fibers.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!