A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electrocatalytic characteristics of a 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone modified carbon-paste electrode in the oxidation of ascorbic acid. | LitMetric

Electrocatalytic characteristics of a 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone modified carbon-paste electrode in the oxidation of ascorbic acid.

Anal Sci

Electroanalytical Chemistry Research Laboratory, Department of Chemistry, Faculty of Basic Sciences, Mazandaran University, Babolsar, Iran.

Published: September 2003

A carbon-paste electrode spiked with 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone was constructed by the incorporation of 1-[4-(ferrocenyl ethynyl)phenyl]-1-ethanone in a graphite powder silicon oil matrix. It shown by cyclic voltammetry and double potential-step chronoamperometry, which this ferrocene derivative modified a carbon-paste electrode, can catalyze the ascorbic acid oxidation in an aqueous buffered solution. It has been found that under the optimum conditions (pH 7.00), the oxidation of ascorbic acid at the surface of this carbon paste modified electrode occurs at a potential of about 260 mV less positive than that of an unmodified carbon-paste electrode. The catalytic oxidation peak current was linearly dependent on the ascorbic acid concentration, and a linear calibration curve was obtained in the range of 6 x 10(-5) M-7 x 10(-3) M of ascorbic acid with a correlation coefficient of 0.9997. The detection limit (2sigma) was determined to be 6.3 x 10(-5) M. This method was also used for the determination of ascorbic acid in some pharmaceutical samples, such as effervescent tablets, ampoules and multivitamin syrup, by using a standard addition method. The reliability of the method was established by a parallel determination against the official method.

Download full-text PDF

Source
http://dx.doi.org/10.2116/analsci.19.1251DOI Listing

Publication Analysis

Top Keywords

ascorbic acid
24
carbon-paste electrode
16
1-[4-ferrocenyl ethynylphenyl]-1-ethanone
12
modified carbon-paste
8
oxidation ascorbic
8
ascorbic
6
acid
6
electrode
5
electrocatalytic characteristics
4
characteristics 1-[4-ferrocenyl
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!