Detection of protease activities with the mass-spectrometry-assisted enzyme-screening (MES) system.

Anal Bioanal Chem

Nephrology, Institute of Toxicology, Charité, Berlin Faculty of Medicine, Garystr 5, Campus Benjamin Franklin, 14195 Berlin, Germany.

Published: December 2003

AI Article Synopsis

  • The MALDI-MES method offers a quick and effective way to detect enzymatic activities without using chromophores or radiolabeling.
  • The process involves immobilizing proteins on beads to avoid interference and ensure accurate measurement of enzymatic reaction products through mass spectrometry.
  • The study illustrates the method's application by monitoring proteolytic activities in porcine renal tissue, validating its capability to assess enzyme presence and the effects of inhibitors.

Article Abstract

The MALDI-MES provides a rapid, sensitive and reproducible alternative approach to existing analytical techniques for the detection of enzymatic activities that does not require a chromophore or radiolabeling. An improved method is presented, by which enzymes with defined substrate specificities can be detected with a MALDI mass spectrometer in complex protein fractions. In order to demonstrate the utility of the new method, in this study we describe the use of MALDI-MES to detect proteolytic activities in a protein extract from porcine renal tissue, which contained several thousand proteins as visualized by 2D electrophoresis. The analytical procedure is based on covalent immobilization of proteins to beads. By immobilizing proteins, autolytic and proteolytic degradation is prevented and the removal of those molecules from the protein fraction is achieved, which otherwise would interfere with the mass spectrometric detection of the enzymatic reaction products. The enzymatic activity is determined by incubating the immobilized proteins with a reaction-specific probe, followed by the analysis of the reaction mixture with the MALDI-MS after defined incubation times. The presence of the target enzyme is validated by locating a signal, which fits the molecular mass of the expected reaction product in the mass spectrum. To demonstrate how to detect proteolytic activities in this system, the reactions catalyzed by endopeptidase, angiotensin-converting enzyme, kallikrein, renin, and urotensin-converting enzyme were monitored. The experiments showed that the MALDI-MES method is sufficient according the quantification to investigate the effects of inhibitors. This is demonstrated using a specific renin inhibitor to inhibit an angiotensin-I generating enzyme activity in a renal protein extract.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-003-2211-8DOI Listing

Publication Analysis

Top Keywords

detection enzymatic
8
detect proteolytic
8
proteolytic activities
8
protein extract
8
detection protease
4
activities
4
protease activities
4
activities mass-spectrometry-assisted
4
mass-spectrometry-assisted enzyme-screening
4
enzyme-screening mes
4

Similar Publications

Among the various cations, the Fe ion is one of the most critical transition metal ions in living cells for many cellular functions and enzymatic activities. The decrease or overloading of Fe can lead to different disruptions in humans. Also, Fe, highly toxic, is very common in all industrial wastewater.

View Article and Find Full Text PDF

Objectives: Urinary steroid profiling after hydrolysis of conjugates is an emerging tool to differentiate aggressive adrenocortical carcinomas (ACC) from benign adrenocortical adenomas (ACA). However, the shortcomings of deconjugation are the lack of standardized and fully validated hydrolysis protocols and the loss of information about the originally conjugated form of the steroids. This study aimed to evaluate the quality of the deconjugation process and investigate novel diagnostic biomarkers in urine without enzymatic hydrolysis.

View Article and Find Full Text PDF

Sensitive non-enzymatic sensing of creatinine in urine using a novel paper-based electroanalytical device.

Talanta

December 2024

Key Laboratory of Consumer Product Quality Safety Inspection and Risk Assessment for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing, China. Electronic address:

Accurate analysis of urinary creatinine levels is of great clinical significance. Non-enzymatic creatinine sensing systems (NECSs) have gained growing development because of higher stability and lower cost compared to enzymatic sensing systems. At present, there is a demand for simple approaches to develop NECSs with high sensitivity.

View Article and Find Full Text PDF

Quantification of L-lactic acid in human plasma samples using Ni-based electrodes and machine learning approach.

Talanta

December 2024

NanoBiosensors and Biodevices Lab, School of Medical Science and Technology, Indian Institute of Technology Kharagpur, West Bengal, 721302, India. Electronic address:

This work presents a robust strategy for quantifying overlapping electrochemical signatures originating from complex mixtures and real human plasma samples using nickel-based electrochemical sensors and machine learning (ML). This strategy enables the detection of a panel of analytes without being limited by the selectivity of the transducer material and leaving accommodation of interference analysis to ML models. Here, we fabricated a non-enzymatic electrochemical sensor for L-lactic acid detection in complex mixtures and human plasma samples using nickel oxide (NiO) nanoparticle-modified glassy carbon electrodes (GCE).

View Article and Find Full Text PDF

Qingwen Zhike prescription (QWZK), a traditional Chinese medicine (TCM) hospital prescription developed in response to the corona virus disease 2019 (COVID-19) pandemic, has demonstrated efficacy in clinical practice. Nevertheless, its specific antiviral components and mechanisms of action remain unclear. This study screened the antiviral compounds against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from Qingwen Zhike prescription and explored the underlying mechanism through chemical composition analysis, serum and lung exposure profiles analysis, high-throughput screening, and transmission electron microscopy (TEM) observation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!