Purpose: To compare the number of postinsertion adjustment visits required by edentulous patients whose dentures were made from border-molded definitive impressions using modeling plastic impression compound (traditional technique) with patients whose dentures were made from border-molded definitive impressions using heavy-body vinyl polysiloxane impression material.

Materials And Methods: In this retrospective clinical study, 78 patients were treated with the traditional technique (custom impression trays border molded with gray modeling plastic impression compound) and 78 were treated with the modified technique (custom impression trays border molded with heavy-body vinyl polysiloxane impression material). In both techniques, definitive wash impressions were made with light-body vinyl polysiloxane impression material. Postinsertion visits were quantified for 1 year after the dentures were inserted.

Results: The average number of adjustment visits for patients treated with the traditional technique was 2.68. The average number of adjustment visits for patients treated with the modified technique was 2.68. The data were compared using Student t tests. There was no significant difference in the number of adjustments required for patients whose dentures were made with either technique (t = 0.000, p = 1.00). There was no significant difference in the number of post-insertion visits required by patients from either population.

Conclusions: Within the limitations of this clinical study, border-molding custom denture impression trays with vinyl polysiloxane impression material provided similar results in terms of postinsertion visits for one year as compared to dentures made from impressions border molded with modeling plastic impression compound.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S1059-941X(03)00082-2DOI Listing

Publication Analysis

Top Keywords

vinyl polysiloxane
16
polysiloxane impression
16
adjustment visits
12
patients dentures
12
modeling plastic
12
plastic impression
12
impression compound
12
traditional technique
12
patients treated
12
impression trays
12

Similar Publications

BACKGROUND A tooth preparation's clinical requirements and geometric configurations should take precedence over material characteristics when advocating for putty reline impression techniques for permanent restorations, since they require a technically sensitive spacer for light body elastomer. We evaluated the linear dimensional accuracy of vinyl polysiloxane-based putty reline impressions with different spacer acquisition techniques in short-span and long-span fixed partial dentures (FPD). MATERIAL AND METHODS A typodont tooth set simulated a 3-unit (short-span) and a 5-unit (long-span) FPD.

View Article and Find Full Text PDF

Interocclusal records (IORs) created with bite registration materials (BRMs) accurately reflect the opposing teeth's physiological and anatomical associations in digital and traditional dentistry. This study assessed the linear dimensional accuracy of vinyl polysiloxane-based scannable and transparent BRMs over obligatory clinical time intervals (1, 24, 72, and 168 h/s). A total of 3 scannable [Flexitime Bite, Occlufast CAD, Virtual CADBite] and 3 transparent [Maxill Bite, Charmflex Bite, Defend ClearBite] VPS-based BRMs were divided into 28 subgroups by time interval: 1, 24, 72, and 168 h/s.

View Article and Find Full Text PDF

Background: The success of a restoration largely depends on the quality of its fit. This study aimed to investigate the fit quality of monolithic zirconia veneers (MZVs) produced through traditional and digital workflows.

Methods: A typodont maxillary right central incisor was prepared.

View Article and Find Full Text PDF

Objective: This study aimed to assess and compare the internal fit of custom-made posts and cores fabricated using digital impressions (DI) and conventional vinyl polysiloxane (VPS) impressions in restorative dentistry.

Materials And Methods: A typodont tooth model, simulating the anatomy of the root canal of a central incisor, was utilized for the study. Two groups were formed, Group A and Group B, and each group provided a total of 18 impressions of two types: DIs and VPS impressions.

View Article and Find Full Text PDF

Effect of index thickness on the accuracy of direct restorations using composite resin injection technique with VPS indices.

J Dent

December 2024

State Key Laboratory of Oral & Max Reconstruction and Regeneration, Key Laboratory of Oral Biomedicine Ministry of Education, Hubei Key Laboratory of Stomatology, School & Hospital of Stomatology, Wuhan University, Wuhan 430079, China. Electronic address:

Objectives: To evaluate the accuracy of direct restorations using transparent vinyl polysiloxane (VPS) indices with different thicknesses for composite resin injection technique.

Methods: Thirty-six standard resin teeth of tooth #11 were divided into 3 groups based on the index thickness including 2, 4, and 6 mm (n = 12). VPS indices were fabricated using customized trays corresponding to each thickness.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!