Background: Although there is a considerable difference in the number of clinical reports of neurologic injury between spinal anesthesia and other regional techniques, there are no animal data concerning a difference in the local anesthetic neurotoxicity between intrathecal and epidural administration. In the current study, the functional and morphologic effects of lidocaine administered intrathecally and epidurally were compared in rats.

Methods: Male rats were implanted with an intrathecal or epidural catheter through L4-L5 vertebra in the caudal direction. In experiment 1, to determine relative anesthetic potency, 16 rats received repetitive injections of 2.5% lidocaine into intrathecal or epidural space in different volumes and were examined for tail flick test for 90 min. In experiment 2, to ascertain whether the relative potency obtained in experiment 1 would apply to other concentrations of lidocaine, additional rats received saline, 1%, 2.5%, or 5% lidocaine in a volume of 20 or 100 microl through the intrathecal or epidural catheter, respectively. In experiment 3, additional rats that received saline, 2.5% lidocaine, or 10% lidocaine in a volume of 20 or 100 microl through the intrathecal or epidural catheter, respectively, were examined for persistent functional impairment and morphologic damage.

Results: In experiment 1, the two techniques produced parallel dose-effect curves that significantly differed from each other. The potency ratio calculated was approximately 4.72 (3.65-6.07):1 for intrathecal:epidural lidocaine. In experiment 2, every lidocaine solution produced a similar increase in tail flick latency for the two techniques. In experiment 3, five of eight rats given 10% intrathecal lidocaine incurred functional impairment 4 days after injection, whereas no rats in the other groups did. Significantly more morphologic damage was observed in rats given 10% intrathecal lidocaine than in those given 10% epidural lidocaine.

Conclusions: Persistent functional impairment occurred only after intrathecal lidocaine. Histologic damage in the nerve roots and the spinal cord was less severe after epidural lidocaine than after intrathecal lidocaine. The current results substantiate the clinical impression that neurologic complications are less frequent after epidural anesthesia than after spinal anesthesia.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00000542-200310000-00032DOI Listing

Publication Analysis

Top Keywords

intrathecal epidural
24
intrathecal lidocaine
16
lidocaine
14
epidural catheter
12
rats received
12
25% lidocaine
12
functional impairment
12
intrathecal
10
epidural
9
neurotoxicity intrathecal
8

Similar Publications

Background: Intraoperative neuromonitoring (IONM) is crucial for the safety of scoliosis surgery, providing real-time feedback on the spinal cord and nerve function, primarily through motor-evoked potentials (MEPs). The choice of anesthesia plays a crucial role in influencing the quality and reliability of these neuromonitoring signals. This systematic review evaluates how different anesthetic techniques-total intravenous anesthesia (TIVA), volatile anesthetics, and regional anesthesia approaches such as Erector Spinae Plane Block (ESPB), spinal, and epidural anesthesia-affect IONM during scoliosis surgery.

View Article and Find Full Text PDF

Background: We hypothesized that patients who received a lower dose of intrathecal morphine (ITM) would have higher postoperative opioid consumption following cesarean delivery.

Methods: Patients who had cesarean deliveries from February 15, 2022, through February 14, 2024 at Baylor Scott & White Medical Center - Temple with single injection spinal or combined spinal epidural anesthesia who did not have labor epidural anesthesia were included. Morphine milligram equivalent (MME) opioid consumption in the first 24 postoperative hours was recorded along with patient demographic, physical, and clinical characteristics.

View Article and Find Full Text PDF

Objective: To compare patient radiation exposure and procedure time for lumbar epidural steroid injections (ESIs) performed under CT-fluoroscopy (CTF) vs spiral CT-guidance.

Materials And Methods: A retrospective cohort study of 767 consecutive lumbar ESIs performed between 2015-2023 using CTF vs spiral CT-guidance was conducted. Patient characteristics (age, sex, weight), procedural characteristics (injection level, type of ESI, trainee participation), and outcomes (patient radiation exposure, procedure time, pain relief, complications) were compared.

View Article and Find Full Text PDF

Background: Post-dural puncture headache (PDPH) after an accidental dural puncture (ADP) is a common complication in obstetric analgesia. It has been proposed that inserting an intrathecal catheter (ITC) after an ADP may reduce PDPH incidence and the need for therapeutic epidural blood patch (EBP). Our primary objective was to assess if the insertion of an ITC after an ADP reduces the incidence of PDPH in obstetric patients.

View Article and Find Full Text PDF

Background: Visceral pain is common in cesarean sections conducted under combined spinal-epidural anesthesia (CSE). Epidural volume extension (EVE) is a technique for enhancing the effect of intrathecal blocks by inducing epidural fluid boluses in the CSE. Whether EVE that uses different drugs can reduce visceral pain during cesarean sections is rarely studied.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!