A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Dynamic QT interval analysis in uraemic patients receiving chronic haemodialysis. | LitMetric

Objective: To analyse the duration of the QT interval and its relationship with heart rate changes in patients with uraemia, before and during haemodialysis.

Methods: QT and RR intervals were measured automatically using a dedicated algorithm with 24-h Holter recordings in 29 patients (15 women) receiving chronic haemodialysis. QT corrected for heart rate (QTc) and the slope of QT/RR linear regression were calculated. Arterial blood pressure (ABP) was measured before and during haemodialysis. Plasma concentrations of K+, Mg2+ and Ca2+ were assessed before and after haemodialysis.

Results: ABP decreased significantly from baseline (102.7 +/- 11.0 mmHg) during the first (100.6 +/- 8.8 mmHg, P < 0.05), second (95.6 +/- 10.6 mmHg, P < 0.05), and third (94.9 +/- 10.3 mmHg, P < 0.05) hours of haemodialysis. QTc was longer during haemodialysis than during a 4-h period of no dialysis (447 +/- 28 ms compared with 429 +/- 22 ms, P < 0.001), and increased progressively during haemodialysis, with the greatest value during the last hour of haemodialysis (454 +/- 32 ms compared with 426 +/- 22 ms, P < 0.001). QT/RR slopes and correlation coefficients were lower during haemodialysis than during the period of no dialysis (0.13 +/- 0.08 compared with 0.20 +/- 0.07, P < 0.001 and 0.48 +/- 0.30 compared with 0.81 +/- 0.20, respectively; P < 0.001), suggesting a reduced ability to adapt the QT interval in response to changes in heart rate. The effects of haemodialysis on QT interval and the QT/RR relationship were greater in women than in men. QTc variations during dialysis were not correlated with changes in ABP, but were inversely related to changes in Ca2+ concentration (r2 = 0.35; P = 0.001).

Conclusions: In patients with uraemia, the haemodialysis session induces a progressive increase in QT interval and modifies its relationship with heart rate. These effects may predispose some individuals to ventricular arrhythmias at the end of and immediately after the haemodialysis session.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004872-200310000-00020DOI Listing

Publication Analysis

Top Keywords

heart rate
16
+/-
12
mmhg 005
12
haemodialysis
11
receiving chronic
8
chronic haemodialysis
8
relationship heart
8
patients uraemia
8
period dialysis
8
+/- compared
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!