A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Viscoelastic behavior and structural properties of the coracoclavicular ligaments. | LitMetric

Viscoelastic behavior and structural properties of the coracoclavicular ligaments.

Scand J Med Sci Sports

Department of Orthopaedic Surgery, Musculoskeletal Research Center, University of Pittsburgh, Pittsburgh, PA 15213, USA.

Published: October 2003

During contact sports such as football, hockey or rugby, the coracoclavicular ligaments are commonly ruptured. Currently, the limited biomechanical data on the properties and function of these ligaments have led to debate on the "gold standard" treatment for these injuries. Therefore, the objective of this study was to characterize the geometry, viscoelastic behavior and structural properties of the coracoclavicular ligaments (n=11). The trapezoid and conoid were found to have similar length (9.6+/-4.4 vs. 11.2+/-4.1 mm) and cross-sectional area (103+/-43 vs. 69+/-51 mm2), respectively (P>0.05). Static and cyclic stress relaxation tests were then performed, followed by uniaxial tensile testing with the insertions of each ligament aligned to ensure a uniform distribution of load across the fibers. No significant differences were observed for the trapezoid and conoid during the static (36+/-8% vs. 31+/-7%) and cyclic (23+/-12% vs. 16+/-6%) stress relaxation tests, respectively (P>0.05). Similarly, no statistically significant differences were found between the trapezoid and conoid for linear stiffness (83+/-40 vs. 70+/-23 N mm(-1)), ultimate load (312+/-133 vs. 266+/- 108 N), energy absorbed at failure (820+/-576 vs. 752+/- 410 N mm), percent elongation (74+/-47% vs. 62+/-22%) and elongation at failure (5.8+/-2.2 vs. 6.1+/-1.6 mm), respectively (P>0.05). A comparison of our data to previous studies suggests that the complex fiber orientation of these ligaments has a significant role in determining the maximum load that can be transferred between the clavicle and scapula by each bone-ligament-bone complex. Our findings also further confirm the functional role of the coracoclavicular ligaments in supporting the upper extremity, and provide data for reconstruction and rehabilitation protocols as well as computational models.

Download full-text PDF

Source
http://dx.doi.org/10.1034/j.1600-0838.2003.00335.xDOI Listing

Publication Analysis

Top Keywords

coracoclavicular ligaments
16
trapezoid conoid
12
viscoelastic behavior
8
behavior structural
8
structural properties
8
properties coracoclavicular
8
stress relaxation
8
relaxation tests
8
ligaments
6
coracoclavicular
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!