A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

(211)At-labeled and biotinylated effector molecules for pretargeted radioimmunotherapy using poly-L- and poly-D-Lysine as multicarriers. | LitMetric

Poly-L- and poly-D-lysine were evaluated as carriers of astatine and biotin for prospective use as effector molecules in pretargeted radioimmunotherapy of micrometastases. The precursor polylysine was derivatized in a three-step, single-pot procedure, including biotinylation with biotin amidocaproic N-hydroxysuccinimide, astatination via the intermediate reagent N-succinimidyl 3-(trimethylstannyl)benzoate, and, finally, charge modification using succinic anhydride. The chemistry was shown to be very facile, with a biotinylation efficiency of 75 +/- 5%, and overall radiochemical yields in the range of 50-70%. After charge modification, no amines could be detected in the final product. The biotin function was unaffected by the chemistry and the radiation, as confirmed by almost complete binding of the effector molecule to avidin beads using a convenient filter tube assay. The effector molecules were evaluated in tumor-free female nude mice with regard to whole-body retention and tissue distribution after i.p. administration. The distribution of the L-isomer effector molecule showed rapid whole-body clearance with low uptake in all tissues, whereas the D-isoform showed whole-body clearance related to uptake in the kidneys. Both D-isomer and L-isomer showed faster blood clearance and generally lower tissue uptakes than labeled antibodies. The normal tissue distribution after the peritoneal administration implies that pretargeting using L-structure polylysine as the effector molecule may give a higher therapeutic index than that achieved in conventional radioimmunotherapy.

Download full-text PDF

Source

Publication Analysis

Top Keywords

effector molecules
12
effector molecule
12
molecules pretargeted
8
pretargeted radioimmunotherapy
8
poly-l- poly-d-lysine
8
charge modification
8
tissue distribution
8
whole-body clearance
8
effector
6
211at-labeled biotinylated
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!