Physical stability of liposomes bearing hemostatic activity.

Chem Phys Lipids

Departament de Físicoquímica, Facultat de Farmàcia, Universitat de Barcelona, Avda. Joan XXIII s/n, 08013, Barcelona, Catalonia, Spain.

Published: October 2003

The physical stability of six liposome systems designed as platelet substitutes was determined on storage at 4 degrees C over a 3-month period under quiescent conditions. Liposomes used were large unilamellar vesicles. Correlation of the n-average mean diameter, polydispersity, zeta-potential and the presence of aminophospholipid on liposome surface (in those preparations which contain phosphatidylethanolamine (PE) and phosphatidylserine (PS)) led to the conclusion that liposomes that mimicked the composition of platelets were the most stable. When a net charge was present in the vesicles (liposomes with PS), the likelihood of aggregation was extremely low. In the period studied, a proportion of 25% of charged lipid (PS) conferred sufficient electrostatic stabilization to prevent vesicle fusion. An increase in this charge did not modify the stability characteristics. PE-containing liposomes behaved in a particular way: when PE content was 50%, the stability of the preparation was limited to 1 month; whereas if the content was 25%, the zeta-potential rose with time, as did the presence of PE in the liposome surface.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0009-3084(03)00086-0DOI Listing

Publication Analysis

Top Keywords

physical stability
8
liposome surface
8
liposomes
5
stability liposomes
4
liposomes bearing
4
bearing hemostatic
4
hemostatic activity
4
activity physical
4
stability liposome
4
liposome systems
4

Similar Publications

A series of compositions NiInSn ( = 0-1) were synthesized by conventional high-temperature synthesis, and as-synthesized samples were checked by powder X-ray diffraction experiments. NiInSn ( < 0.7) mainly forms the ternary variant of the CoSn-type structure (6/), whereas, = 0.

View Article and Find Full Text PDF

Objective: Carotid artery stenosis, primarily caused by atherosclerosis, is a major risk factor for ischemic stroke. Carotid endarterectomy (CEA) and carotid artery stenting (CAS) are established interventions to reduce stroke risk and restore cerebral blood flow. However, the effect of these treatments on circadian rhythms, and their influence on stroke recovery, remains underexplored.

View Article and Find Full Text PDF

Background: Several studies have suggested that approximately 10 hours of inactivity can reduce motor performance. Specifically, restricted lower limb movement may impair postural stability, subsequently increasing the incidence of falls. However, the relationship between postural sway and its related factors remains unclear.

View Article and Find Full Text PDF

Introduction: Whether in industrial production or daily life, froth plays an important role in many processes. Sometimes, froth exists as a necessity and is also regarded as the typical characteristic of products, e.g.

View Article and Find Full Text PDF

Purpose: Plantar soft tissue properties affect foot biomechanics during movement. This study aims to explore the relationship between plantar pressure features and soft tissue stiffness through interpretable neural network model. The findings could inform orthotic insole design.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!