We used perfluorocarbon liquids in the management of 6 cases of posterior dislocation of the lens and 7 cases of (sub-) luxation of a posterior chamber intraocular lens (IOL). The perfluorocarbon liquid was injected into the vitreous cavity after complete vitrectomy, to bring back the lens or IOL to the posterior chamber where it can be easily removed. The main characteristics of perfluorocarbon liquids used in this indication are their high specific gravity and their good surface tension. Because of these two qualities, when injected in a vitrectomized eye, the perfluorocarbon liquid forms a bubble, filling the vitreous cavity from the posterior pole to the ora serrata with the dislocated lens or IOL floating on its surface. We found this technique to be helpful and quite atraumatic in this difficult surgical situation. Complications included regressive corneal edema in 6 cases and retinal dialysis with localized detachment in 3 cases.
Download full-text PDF |
Source |
---|
Clin Ophthalmol
January 2025
Sengi, Penniac, NB, Canada.
Purpose: To evaluate visual outcomes and quality of vision following bilateral implantation of a hydrophobic acrylic intraocular lens (IOL) in eyes targeted for emmetropia.
Methods: This was a prospective, single arm study. Subjects were bilaterally implanted with the Clareon PanOptix IOL and evaluated at 1 and 3 months postoperatively.
J AAPOS
January 2025
Johns Hopkins University Wilmer Eye Institute, Baltimore, Maryland. Electronic address:
Background Recommendations regarding long-term postoperative activity are intended to prevent adverse events, but no common policy or best practice exists among ophthalmologists for pediatric patients. We surveyed ophthalmologists on their postoperative guidelines after the one-month postoperative period following childhood cataract and glaucoma surgeries. Methods A 28-question anonymous Qualtrics survey was distributed via listservs and social media.
View Article and Find Full Text PDFLife (Basel)
January 2025
Centro Oftalmológico Charles, Buenos Aiers C1116, Argentina.
Background: The aim of this study was to evaluate visual outcomes and patient satisfaction after bilateral implantation of a new hydrophobic acrylic intraocular lens called Clareon (Alcon) using the mini-monovision technique.
Methods: A single-center, prospective, nonrandomized study was conducted in Tandil (Buenos Aires, Argentina), including patients scheduled for cataract surgery. To achieve mini-monovision, the spherical equivalent was calculated between -0.
Life (Basel)
January 2025
Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, 61-553 Poznan, Poland.
To compare the accuracy of seven artificial intelligence (AI)-based intraocular lens (IOL) power calculation formulas in medium-long Caucasian eyes regarding the root-mean-square absolute error (RMSAE), the median absolute error (MedAE) and the percentage of eyes with a prediction error (PE) within ±0.5 D. Data on Caucasian patients who underwent uneventful phacoemulsification between May 2018 and September 2023 in MW-Med Eye Center, Krakow, Poland and Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Kyiv, Ukraine were reviewed.
View Article and Find Full Text PDFBiomedicines
January 2025
Department of Ophthalmology, UHC Sestre Milosrdnice, 10000 Zagreb, Croatia.
We describe a novel experimental device, the VaMa (Vatavuk and Marić) artificial intraocular lens (IOL) capsule, and a method that enables all IOL types to be implanted in the bag. We present the application of the device and the procedure in patients with aphakia and native capsule damage and without efficient capsular support. The VaMa device and the method facilitate IOL exchange due to refractive errors and, in the case of their invention, the implementation of superior IOLs in the future.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!