Download full-text PDF |
Source |
---|
Open Heart
January 2025
Department of Cardiology, University Hospital Basel, Basel, Switzerland.
Background: The majority of functional ischemia tests in patients with suspected chronic coronary syndromes (CCS) yield normal results. Implementing gatekeepers for patient preselection, such as pretest probability (PTP) and/or coronary artery calcium score (CACS), could reduce the number of normal scan results, radiation exposure and costs. However, the efficacy and safety of these approaches remain unclear.
View Article and Find Full Text PDFCureus
December 2024
Radiation Oncology, Thomas Jefferson University Hospital, Philadelphia, USA.
Purpose Low-dose total skin electron beam therapy (LD-TSEBT) has recently gained popularity in treating mycosis fungoides (MF) due to its reduced toxicity and favorable response rates. Combining accelerated LD-TSEBT with the modified Stanford technique (mST), a condensed cycling approach, offers a promising and convenient option. However, in vivo dosimetry data confirming the effectiveness of this approach is limited.
View Article and Find Full Text PDFEnviron Sci Technol
January 2025
Department of Environmental and Resource Engineering, Technical University of Denmark, DTU Risø Campus, DK-4000 Roskilde, Denmark.
U and U are proven to be useful tracers to investigate upper-ocean hydrodynamics due to their source-specific isotopic ratios and conservative behaviors in the open ocean. However, their application in the Pacific Ocean has been limited by scarce observations and unclear source-term information. Here, we present our observations of U and U in the western North Pacific Subtropical Gyre (NPStG), showing the presence of a source of anthropogenic U featured by a low U/U ratio (∼1 × 10), which is an order of magnitude lower than the global fallout signature (∼2 × 10).
View Article and Find Full Text PDFJ Nucl Med
January 2025
Department of Nuclear Medicine, University Hospital Würzburg, Würzburg, Germany
Dosimetry is integral to informed implementation of radiopharmaceutical therapies, enabling personalized treatment planning and ensuring patient safety by calculating absorbed doses to organs and tumors. As the therapeutic radiopharmaceutical field continues to expand, dosimetry software has emerged as a crucial tool for optimization of treatment efficacy. This review discusses key features and capabilities that current dosimetry software solutions have or should have in the future.
View Article and Find Full Text PDFLasers Med Sci
January 2025
Universidade Estadual do Oeste do Paraná - Unioeste, Campus Cascavel, Universitaria St. 2069, CascavelParaná, 85819-110, Brazil.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!