We examined jugular venous oxygen saturation data in 17 pediatric patients less than 1 year of age undergoing hypothermic cardiopulmonary bypass (CPB). Jugular venous oxygen saturations (JvO2SATS) were measured before bypass and during the active core cooling portion of CPB. The study intervals during CPB included 1 minute after initiation of CPB, at a tympanic membrane temperature of 15 degrees C, and at a rectal temperature of 15 degrees C. During these measurement intervals, there were no significant changes in mean arterial pressure, pump flow rate, arterial oxygen saturation, mixed venous oxygen saturation, carbon dioxide tension, or hematocrit. Six of the 17 patients (29%) demonstrated a significantly lower JvO2SAT (87.1% +/- 6.3% versus 98.1% +/- 0.9%) at a tympanic membrane temperature of 15 degrees C. Patients demonstrating jugular venous desaturation could not be predicted from continuous monitoring of tympanic membrane and rectal temperatures or through on-line measurements of mixed venous oxygen saturation. Low JvO2SAT suggests higher levels of cerebral metabolism and cerebral uptake of oxygen. In the presence of deep hypothermic CPB and stable anesthetic levels, the most likely cause of a low JvO2SAT is inadequate cerebral cooling. We believe JvO2SAT monitoring may be an important adjunct to conventional temperature monitoring in the patient undergoing deep hypothermic CPB or total circulatory arrest.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0003-4975(92)91022-2DOI Listing

Publication Analysis

Top Keywords

venous oxygen
16
oxygen saturation
16
jugular venous
12
tympanic membrane
12
temperature degrees
12
temperature monitoring
8
membrane temperature
8
mixed venous
8
low jvo2sat
8
deep hypothermic
8

Similar Publications

Background: Cerebral autoregulation is a robust regulatory mechanism that stabilizes cerebral blood flow in response to reduced blood pressure, thereby preventing cerebral ischaemia. Scientists have long believed that cerebral autoregulation also stabilizes cerebral blood flow against increases in intracranial pressure, which is another component that determines cerebral perfusion pressure. However, this idea was inconsistent with the complex pathogenesis of normal pressure hydrocephalus, which includes components of chronic cerebral ischaemia due to mild increases in intracranial pressure.

View Article and Find Full Text PDF

Balloon atrioseptostomy for transposition of the great arteries in Europe: characteristics and outcomes.

Rev Esp Cardiol (Engl Ed)

January 2025

Pediatric Cardiology Department, M3C National reference center, Hospital Necker- Enfants Malades, Assistance Publique-Hôpitaux de Paris, University Paris Cité, Paris, France.

Introduction And Objectives: Balloon atrial septostomy (BAS) improves oxygenation in neonates with transposition of the great arteries (TGA) and restrictive foramen ovale. Currently, there is a global shortage of dedicated BAS catheters, while new unmarked catheters have recently become available at some European centers. This study aimed to characterize BAS outcomes using the currently available BAS catheters in Europe.

View Article and Find Full Text PDF

Multi-disciplinary treatment of broncho-esophageal fistula in a high-risk single-lung patient.

J Cardiothorac Surg

January 2025

Section of Cardiothoracic Surgery, Department of Heart Disease, Haukeland University Hospital, Jonas Lies vei 65, 5021, Bergen, Norway.

Background: A broncho-esophageal fistula (BEF) is a medical and surgical disaster. Treatment of BEF is often limited to palliative stent treatment that may migrate or cause erosions and tissue necrosis. Surgical repair of BEF is the only established definite treatment.

View Article and Find Full Text PDF

Background: Continuous veno-venous hemodiafiltration (CVVHDF) is used in critically ill patients, but its impact on O₂ and CO₂ removal, as well as the accuracy of resting energy expenditure (REE) measurement using indirect calorimetry (IC) remains unclear. This study aims to evaluate the effects of CVVHDF on O₂ and CO₂ removal and the accuracy of REE measurement using IC in patients undergoing continuous renal replacement therapy.

Design: Prospective, observational, single-center study.

View Article and Find Full Text PDF

Mediastinal mass syndrome represents a major threat to respiratory and cardiovascular integrity, with difficult evidence-based risk stratification for interdisciplinary management. We conducted a narrative review concerning risk stratification and difficult airway management of patients presenting with a large mediastinal mass. This is supplemented by a case report illustrating our individual approach for a patient presenting with a subtotal tracheal stenosis due to a large cyst of the thyroid gland.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!