We have experimentally produced a ureteral stent which prevents vesicorenal reflux. This stent has a thin silicon sleeve at its distal end (intravesical portion). In a model experiment the sleeve demonstrated an excellent capability to prevent reflux. The sleeve allowed flow of fluid with minimal pressure rise. A patient with bilateral ureteral obstruction was managed with endoscopic insertion of a sleeved stent in the right ureter and a usual pigtail stent in left ureter. During cystography vesicorenal reflux was not observed on the right side while reflux occurred on the left side. Excretory urography forty days after stent placement demonstrated recovery of renal function and maintenance of drainage in both renal units. Thus, the drainage characteristic of this stent appears to be approximately the same as that of usual stent.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0090-4295(92)90381-6DOI Listing

Publication Analysis

Top Keywords

stent
8
ureteral stent
8
vesicorenal reflux
8
prototype reflux-preventing
4
reflux-preventing ureteral
4
stent clinical
4
clinical experimentally
4
experimentally produced
4
produced ureteral
4
stent prevents
4

Similar Publications

Esophago-jejunal anastomoses fistula could be mortal. Currently there is a wide therapeutic measure ranging from conservative management, endoscopic therapy and surgery. Endoscopic management has been positioned above other strategies due to minimal invasion which improves survival and reduces mortality.

View Article and Find Full Text PDF

Purpose: Angioplasty of lower extremity arteries with calcification may result in flow-limiting dissection requiring bail-out stenting with unfavorable long-term outcomes. Vessel preparation prior to angioplasty may improve immediate results of the angioplasty and long-term patency. This prospective study assessed the 12-month outcomes of patients who underwent novel vessel preparation catheter, the FLEX Vessel Prep™ System (FLEX VP), prior to drug-coated balloon angioplasty (DCB-PTA).

View Article and Find Full Text PDF

Diffuse coronary artery disease (CAD) impacts the immediate hemodynamic and clinical outcomes of percutaneous coronary intervention (PCI). We evaluated whether the diffuse pattern of CAD derived from angiographic Quantitative flow ratio (QFR) impacts the immediate hemodynamic outcome post-PCI and the medium term predicted vessel-oriented composite endpoint (VOCE). Paired pre-procedure QFRs were assessed in 503 patients and 1022 vessels in the Multivessel TALENT (MVT) trial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!